Product Catalogue
Full Product Catalogue
Browse industrial electrical components, automation hardware and control systems, with technical specifications, features and application areas for each listed product.
Catalogue listings currently cover Siemens, Schneider Electric and ABB products. Mitsubishi Electric and INVT products are also supplied — send us your requirement.
Specifications, standards and approvals shown are those published by the manufacturers for the ranges listed, and they vary by model and revision. Confirm them against the current manufacturer datasheet before ordering. Mahalaxmi Autotech makes no certification or approval claim of its own for these products.
- 5Supply-partner brands
- 3Brands with listings
- 3Product categories
- 6Sectors served
Miniature Circuit Breakers (MCBs)
2 Products
Schneider Electric Acti9 iC60N MCB
Technical Specifications
| Rated Current | 1A to 63A |
| Poles | 1P, 2P, 3P, 4P |
| Breaking Capacity | 6 kA (IEC 60898) |
| Tripping Characteristic | B, C, D curves |
| Operating Voltage | 230/400V AC |
| Frequency | 50/60 Hz |
| Operating Temperature | -25°C to +70°C |
| Standard | IEC 60898-1 / EN 60898-1 |
| Mounting | DIN Rail (TH35) |
| Protection Degree | IP20 |
Key Features
- ✓High breaking capacity (6kA) for demanding environments
- ✓Wide current range from 1A to 63A in single product family
- ✓Suitable for both single and three-phase systems
- ✓Compatible with Acti9 modular accessories (auxiliary contacts, alarm contacts)
- ✓Clearly marked ON/OFF status for operator visibility
- ✓Compact modular design — 18mm per pole
Application Areas
ABB S200 Series MCB
| Rated Current | 0.5A to 63A |
| Poles | 1P, 2P, 3P, 4P |
| Breaking Capacity | 6 kA / 10 kA options |
| Tripping Characteristic | B, C, D curves |
| Operating Voltage | 230/400V AC |
| Frequency | 50/60 Hz |
| Operating Temperature | -25°C to +55°C |
| Standard | IEC/EN 60898-1 |
| Mounting | DIN Rail (TH35) |
| Width per Pole | 17.5 mm |
Key Features
- ✓Slim 17.5mm per pole design saves panel space
- ✓Available in B, C and D characteristics for all application types
- ✓High immunity to vibration — ideal for industrial environments
- ✓Compatible with full ABB S200 accessory range
- ✓Double terminal connection for loops and ring mains
Application Areas
Moulded Case Circuit Breakers (MCCBs)
2 ProductsSchneider Electric EasyPact EZC MCCB
| Rated Current | 16A to 630A |
| Poles | 3P, 4P |
| Breaking Capacity (Icu) | 25 kA to 70 kA at 415V |
| Trip Unit | Thermal-magnetic (TM-D) |
| Operating Voltage | Up to 690V AC |
| Frequency | 50/60 Hz |
| Frame Sizes | EZC100, EZC250, EZC400, EZC630 |
| Standard | IEC 60947-2 |
| Mounting | Fixed / Plug-in / Withdrawable |
| Protection Degree | IP40 (front face) |
Key Features
- ✓Adjustable thermal-magnetic trip for precise motor protection
- ✓High breaking capacity up to 70kA for short-circuit protection
- ✓Available in fixed, plug-in and withdrawable mounting configurations
- ✓Rotary handle accessory available for door-mounted operation
- ✓Compatible with shunt trip, undervoltage release and auxiliary contacts
- ✓Wide current range in a single compact product family
Application Areas
ABB Tmax T Series MCCB
| Rated Current | 16A to 800A |
| Poles | 3P, 4P |
| Breaking Capacity (Icu) | Up to 200 kA at 415V |
| Trip Unit | TMD (thermal-magnetic) / PR221 (electronic) |
| Operating Voltage | Up to 690V AC |
| Frequency | 50/60 Hz |
| Standard | IEC 60947-2 |
| Mounting | Fixed / Plug-in / Withdrawable |
| Service Life (Electrical) | Up to 25,000 operations |
| Communication (optional) | Modbus RTU / Profibus |
Key Features
- ✓Extremely high breaking capacity — up to 200kA for high fault-level systems
- ✓Electronic trip unit with LSIG protection (Long time, Short time, Instantaneous, Ground fault)
- ✓Optional communication module for remote monitoring via Modbus/Profibus
- ✓Zone Selective Interlocking (ZSI) for faster fault clearing
- ✓Up to 25,000 electrical operations for long service life
Application Areas
Control Panels
3 Products
Motor Control Center (MCC) Panel
| Voltage | 415V AC, 3-phase, 50Hz |
| Incomer Rating | 100A to 3200A (as specified) |
| Busbar Material | Copper / Aluminium |
| Protection Degree | IP42 / IP54 (NEMA 12 optional) |
| Mounting | Floor-standing, cubicle type |
| Standard | To project specification |
| Starter Types | DOL, Star-Delta, Soft Starter, VFD |
| Protection Relays | Overload, Earth fault, Under/Over voltage |
| Metering | Ammeter, Voltmeter, Power meter (optional) |
| Communication | Modbus / Profibus (optional) |
Key Features
- ✓Custom-engineered to plant layout and motor schedule
- ✓Factory tested before dispatch — full FAT (Factory Acceptance Test)
- ✓Draw-out or fixed type compartments for ease of maintenance
- ✓Integrated VFD and soft-starter compartments available
- ✓Busbar sized to project specification
- ✓Optional PLC integration for automated motor sequencing
Application Areas

Power Control Center (PCC) Panel
| Voltage | 415V AC, 3-phase, 4-wire, 50Hz |
| Incomer Rating | 630A to 6300A |
| Breaker Type | ACB (Air Circuit Breaker) / MCCB |
| Busbar | Copper — sized to project specification |
| Protection Degree | IP42 / IP54 |
| Standard | To project specification |
| Metering | Multifunction energy meter, power analyser |
| Bus Configuration | Single / Double bus with coupler |
| Communication | Modbus RTU / Ethernet (optional) |
Key Features
- ✓Handles main incomer from DG sets, transformers and utility
- ✓Auto-changeover between grid and DG supply (optional)
- ✓Zone Selective Interlocking (ZSI) for selective fault clearing
- ✓Integrated multifunction meters for power quality monitoring
- ✓Designed to the project's fault-level requirements
Application Areas

Sub-Main & Final Distribution Board (DB)
| Voltage | 415V / 240V AC |
| Incomer | MCCB 63A to 400A |
| Outgoing Ways | 8 to 36 ways (MCB) |
| MCB Rating | 6A to 63A |
| Protection Degree | IP43 / IP65 (outdoor) |
| Enclosure | Sheet steel / GRP (Glass Reinforced Plastic) |
| Busbar | Copper tinned, 63A to 400A rated |
| Mounting | Surface / Flush / Pole-top |
| Standard | To project specification |
Key Features
- ✓Available in surface and flush-mount configurations
- ✓GRP enclosures available for corrosive and outdoor environments
- ✓RCD (Residual Current Device) integration for earth leakage protection
- ✓Clear circuit directory label holder as standard
- ✓Suitable for three-phase and single-phase final distribution
Application Areas
Bus Bars & Energy Meters
2 ProductsSchneider Electric PowerLogic PM5100 Energy Meter
| Measurement Accuracy | Class 0.5S (IEC 62053-22) |
| Voltage Input | Up to 690V L-L (direct) |
| Current Input | 1A or 5A (via CT) |
| Parameters Measured | V, I, kW, kVA, kVAR, PF, Hz, kWh, THD |
| Harmonics | Up to 31st harmonic |
| Display | Backlit LCD, 4-line |
| Communication | Modbus RTU (RS-485) / Ethernet (PM5310) |
| Digital Inputs/Outputs | 2 DI, 2 DO (relay) |
| Mounting | Panel cut-out 92 × 92 mm |
| Standard | IEC 62053-22 / MID (EN 50470-1/3), as stated by Schneider Electric |
Key Features
- ✓Class 0.5S accuracy (IEC 62053-22)
- ✓Harmonic analysis up to 31st order for power quality monitoring
- ✓Modbus RTU communication for SCADA/BMS integration
- ✓Demand monitoring with configurable demand intervals
- ✓Data logging with time-stamped records
Application Areas
Schneider Electric Canalis Bus Bar Trunking System
| Rated Current | 25A to 5000A |
| Voltage | 415V / 690V AC, 3-phase |
| Conductor Material | Copper (KS/KT) / Aluminium (KN) |
| IP Rating | IP55 (KS), IP40 (KT/KN) |
| Short Circuit Withstand | Varies by model — see Schneider Electric datasheet |
| Tap-off Units | Every 0.5m along the run |
| Phases | 3P+N+PE (5 conductor) |
| Standard | IEC 61439-6 |
| Installation | Horizontal / Vertical / Overhead |
Key Features
- ✓Tap-off units every 0.5m — flexible power access along the run
- ✓Eliminates cable trays and reduces installation time significantly
- ✓IP55 version suitable for wet and dusty environments
- ✓Pre-manufactured sections reduce on-site wiring errors
- ✓Supports future load additions without system shutdown
Application Areas
PLCs — Programmable Logic Controllers
4 ProductsSiemens SIMATIC S7-1200 PLC
| CPU Variants | CPU 1211C to 1217C |
| Digital I/O (onboard) | 6 DI / 4 DO to 14 DI / 10 DO |
| Analog I/O (onboard) | 2 AI / 0 AO to 2 AI / 2 AO |
| Program Memory | 75 KB to 150 KB |
| Data Memory | 100 KB to 4 MB |
| Communication | PROFINET (1–3 ports), RS-485 optional |
| Signal Modules | Up to 8 SM (I/O expansion) |
| Motion Control | Up to 4 axes (via TO technology objects) |
| Supply Voltage | 24V DC / 120-240V AC |
| Programming Software | TIA Portal V15/V16/V17/V19 |
Key Features
- ✓Integrated PROFINET port for direct HMI and network connection
- ✓TIA Portal integration for unified engineering across PLC, HMI, and drives
- ✓Built-in motion control for up to 4 servo/stepper axes
- ✓OPC UA server for Industry 4.0 and IIoT connectivity
- ✓Compact design — fits in tight control panel spaces
- ✓PID control, high-speed counters and pulse outputs built-in
Application Areas

Siemens SIMATIC S7-1500 PLC
| CPU Range | CPU 1511-1 PN to CPU 1518-4 PN/DP |
| Bit Performance | 1 ns to 60 ns per instruction |
| Work Memory | 150 KB to 60 MB |
| Communication | PROFINET (2–3 ports), PROFIBUS DP |
| I/O Expansion | Via PROFINET / PROFIBUS ET 200 |
| Safety (F-CPU) | Fail-safe F-CPU variants available (ratings per Siemens documentation) |
| Motion Control | Up to 128 axes |
| Display | Integrated TFT display on CPU (colour) |
| Cybersecurity | Access protection, copy protection, OPC UA |
| Programming | TIA Portal, LAD, FBD, SCL, STL, GRAPH |
Key Features
- ✓1 ns bit processing — fastest response for high-speed processes
- ✓Fail-safe F-CPU variants available for safety applications
- ✓Up to 128 motion axes with built-in motion control library
- ✓Integrated colour display on CPU for on-site diagnostics
- ✓OPC UA server/client for IIoT and MES connectivity
- ✓Proven cybersecurity — know-how protection, copy protection
Application Areas
Schneider Electric Modicon M221 Logic Controller
| Digital I/O | 16 to 40 (onboard) |
| Analog I/O | 2 AI built-in (some variants) |
| Program Memory | 512 KB |
| Data Memory | 256 KB |
| Communication | Ethernet (Modbus TCP), RS-485, USB |
| High-Speed I/O | 4 HSC (100 kHz), 2 PTO (100 kHz) |
| Supply Voltage | 24V DC / 100-240V AC |
| Output Types | Relay / Transistor (NPN/PNP) |
| Programming | EcoStruxure Machine Expert Basic (LD, IL) |
| Expansion | Up to 7 I/O expansion modules |
Key Features
- ✓Ethernet built-in — Modbus TCP/IP for SCADA connectivity
- ✓High-speed counters at 100 kHz for encoder and speed measurement
- ✓Pulse Train Output (PTO) for stepper motor control
- ✓Compact size for space-constrained machine panels
- ✓Free EcoStruxure Machine Expert Basic programming software
Application Areas
Schneider Electric Modicon M340 PAC
| CPU Processing | 0.1 µs per boolean instruction |
| Program Memory | Up to 8 MB |
| I/O Capacity | Up to 1024 I/O (local + remote) |
| Communication | Ethernet, PROFIBUS DP, CANopen, Modbus |
| Rack Slots | 4 to 12 slot racks |
| Redundancy | Hot Standby CPU redundancy (optional) |
| Supply Voltage | 24V DC / 100-240V AC |
| Programming | EcoStruxure Control Expert (IEC 61131-3) |
| Operating Temperature | 0°C to +60°C |
Key Features
- ✓Hot Standby redundancy for high-availability process control
- ✓Multi-network support — PROFIBUS, CANopen, Modbus, Ethernet simultaneously
- ✓Up to 1024 I/O for large process installations
- ✓Supports IEC 61131-3 languages — LD, FBD, SFC, ST, IL
- ✓Widely used in water treatment and oil & gas process control in India
Application Areas
VFDs — Variable Frequency Drives
3 ProductsSiemens SINAMICS G120 Variable Frequency Drive
| Power Range | 0.37 kW to 250 kW |
| Input Voltage | 200–240V / 380–480V / 500–690V AC |
| Output Frequency | 0 to 550 Hz |
| Control Mode | V/f, Sensorless Vector, Closed-loop Vector |
| Communication | PROFINET, PROFIBUS, USS, Modbus RTU |
| Safety Functions | STO, SS1, SLS, SDI — SIL 2 (per Siemens) |
| Overload Capacity | 150% for 60 sec / 200% for 3 sec |
| Protection Degree | IP20 (chassis) / IP55 (SINAMICS G120C) |
| Braking | DC braking / Dynamic braking (with resistor) |
| Energy Savings | Energy-saving V/f mode for pumps & fans |
Key Features
- ✓Integrated safety functions (STO/SS1)
- ✓PROFINET communication for TIA Portal integration with S7 PLCs
- ✓Advanced vector control for precise speed and torque regulation
- ✓Energy-saving algorithm reduces energy consumption on pump and fan loads
- ✓Modular design — separate Control Unit and Power Module for easy service
- ✓Available in IP55 compact version (G120C) for harsh environments
Application Areas
Schneider Electric Altivar Machine ATV320 VFD
| Power Range | 0.18 kW to 15 kW |
| Input Voltage | 200–240V 1ph/3ph / 380–500V 3ph |
| Output Frequency | 0.5 to 500 Hz |
| Control Mode | V/f, Sensorless Flux Vector, Flux Vector |
| Communication | Modbus RTU, CANopen, PROFIBUS, EtherNet/IP |
| Safety | Integrated STO safety function (ratings per Schneider Electric documentation) |
| Integrated EMC Filter | Yes — filter class depends on model (see datasheet) |
| Overload | 170% for 60 sec (normal duty) |
| Protection Degree | IP20 / IP21 (with cover) |
| Braking Transistor | Built-in (up to 7.5 kW) |
Key Features
- ✓Integrated EMC filter — reduces panel space and cost
- ✓Built-in braking transistor up to 7.5 kW for quick deceleration
- ✓Single-phase input (200–240V) available for small machine applications
- ✓Multiple fieldbus protocols — flexible connectivity with any PLC brand
- ✓Integrated STO (Safe Torque Off) safety function
Application Areas

ABB ACS580 General Purpose VFD
| Power Range | 0.75 kW to 250 kW |
| Input Voltage | 380–480V AC, 3-phase |
| Control Method | DTC (Direct Torque Control) / Scalar |
| Output Frequency | 0 to 500 Hz |
| Communication | Modbus RTU, EtherNet/IP, PROFIBUS, PROFINET |
| Built-in PLC | Yes — for standalone pump/fan logic |
| Energy Optimiser | Built-in energy optimisation function |
| Protection Degree | IP21 / IP55 (frame R1–R9) |
| EMC Filter | C2 integrated (standard) |
| Overload | 110% continuous / 150% for 1 min |
Key Features
- ✓ABB Direct Torque Control (DTC) — fastest and most accurate torque response
- ✓Built-in application PLC eliminates need for external controller in simple applications
- ✓Energy Optimiser function maximises savings on pump and fan loads
- ✓Multi-pump control built-in for up to 3 pump cascade control
- ✓Assistive control panel with real-time help text for easy commissioning
Application Areas
HMIs — Human-Machine Interfaces
3 ProductsSiemens SIMATIC KTP700 Basic Panel HMI
| Display Size | 7" widescreen TFT |
| Resolution | 800 × 480 pixels |
| Colour Depth | 64K colours |
| Touch Screen | Resistive touch + 8 function keys |
| Communication | PROFINET (Ethernet) |
| Compatible PLCs | SIMATIC S7-1200 / S7-1500 / S7-300/400 |
| Project Memory | 10 MB |
| Number of Tags | 800 power tags |
| Operating System | Windows CE 6.0 |
| Supply Voltage | 24V DC |
Key Features
- ✓TIA Portal configuration — same engineering environment as S7 PLCs
- ✓8 configurable function keys for critical process shortcuts
- ✓Bright 64K colour TFT — clearly readable in industrial lighting
- ✓800 power tags sufficient for most machine applications
- ✓Panel cut-out mount — IP65 front face, dust and water protected
Application Areas
Siemens SIMATIC TP1200 Comfort Panel HMI
| Display Size | 12.1" widescreen TFT |
| Resolution | 1280 × 800 pixels |
| Colour Depth | 16 million colours |
| Touch Type | Capacitive multi-touch (10-point) |
| Communication | PROFINET + PROFIBUS DP (dual) |
| USB Ports | 2 × USB 2.0 Host |
| Project Memory | 24 MB (user memory) |
| Number of Tags | Unlimited (Comfort class) |
| Alarms | Up to 20,000 alarm events |
| Recipes | Up to 500 recipes, 1000 records each |
Key Features
- ✓16M colour capacitive multi-touch — smartphone-like operator experience
- ✓Dual PROFINET + PROFIBUS ports for connection to mixed PLC networks
- ✓Unlimited tags and advanced recipe management
- ✓JavaScript scripting for custom visualization logic
- ✓High-resolution trend display for process parameter tracking
- ✓OPC UA client for MES and ERP data exchange
Application Areas
Schneider Electric Magelis HMIGTU Series HMI
| Display Sizes | 3.5" / 5.7" / 7" / 10.4" / 15" |
| Resolution | 320×240 to 1024×768 pixels |
| Touch Type | Resistive analog touch |
| Communication | Ethernet, RS-232, RS-485, USB Host |
| Compatible PLCs | Modicon M221/M340/Premium/Quantum |
| Multi-Protocol | Modbus TCP, Uni-Telway, EtherNet/IP |
| Project Memory | Up to 128 MB (SD Card expandable) |
| Configuration | Vijeo Designer (free download) |
| Protection Degree | IP65 (front panel) |
| Supply Voltage | 24V DC |
Key Features
- ✓Scalable platform — same software for all panel sizes
- ✓Multi-protocol driver library — connects to virtually any PLC brand
- ✓SD card expandable memory for large project archives
- ✓IP65 front panel rating — fully dust-tight and water-jet protected
- ✓Free Vijeo Designer software with no per-project licensing
Application Areas
Contactors & Relays
2 ProductsSchneider Electric TeSys D AC Contactor
| Rated Current (AC-3) | 9A to 95A |
| Motor Power (400V AC-3) | 4 kW to 45 kW |
| Poles | 3P (main) + 1NO+1NC (auxiliary) |
| Coil Voltage | 24V / 48V / 110V / 230V / 415V AC & DC |
| Rated Voltage | Up to 690V AC |
| Electrical Endurance | Up to 10 million operations (AC-3) |
| Standard | IEC 60947-4-1 |
| Mounting | DIN Rail / Screw mounting |
| Operating Temperature | -40°C to +60°C |
Key Features
- ✓Wide coil voltage range — single contactor supports multiple control voltages
- ✓Up to 10 million electrical operations — exceptional endurance
- ✓Extensive accessory range — timers, auxiliary blocks, mechanical interlocks
- ✓Operating at -40°C — suitable for cold storage and outdoor enclosures
- ✓Available with built-in suppressor for reduced coil interference
Application Areas
Schneider Electric Zelio Logic Smart Relay
| Digital Inputs | 10 to 40 (depending on model) |
| Digital Outputs | 6 to 24 (relay / transistor) |
| Analog Inputs | Up to 4 (0-10V / 4-20mA, some models) |
| Supply Voltage | 12V DC / 24V DC / 100-240V AC |
| Timers | Up to 32 (TON, TOF, TP, etc.) |
| Counters | Up to 16 (up/down, HSC) |
| Communication | Modbus RTU (SR2E / SR3 models) |
| Display | Built-in LCD (SR2 models) |
| Programming | Ladder (on-device) / Zelio Soft 2 (PC) |
Key Features
- ✓Can be programmed directly from front panel without PC
- ✓Replaces complex relay-timer wiring with programmable logic
- ✓Free Zelio Soft 2 PC programming and simulation software
- ✓Modbus RTU communication for SCADA integration
- ✓Expandable I/O modules for applications up to 40 I/O
Application Areas
Motor Starters
1 ProductSchneider Electric Star-Delta Motor Starter
| Motor Power Range | 22 kW to 315 kW |
| Starting Current Reduction | Reduced to 33% of DOL starting current |
| Contactors Required | 3 × TeSys D (Main, Star, Delta) |
| Timer | LAD8N10 pneumatic or electronic timer |
| Transition Time | Adjustable 3 to 30 seconds |
| Overload Relay | LRD series thermal overload |
| Interlocking | Electrical + mechanical interlock |
| Supply Voltage | 415V AC, 3-phase, 50Hz |
| Coil Voltage | 24V / 110V / 230V / 415V AC |
Key Features
- ✓Reduces starting current to 33% — prevents voltage dips on supply
- ✓Adjustable star-to-delta transition time for smooth acceleration
- ✓Electrical and mechanical interlock prevents star/delta simultaneous close
- ✓Complete kit available — 3 contactors + timer + overload as set
- ✓Cost-effective alternative to soft starters for constant-load applications
Application Areas
Moulded Case Circuit Breakers (MCCBs)
2 ProductsSchneider Electric EasyPact EZC MCCB
| Rated Current | 16A to 250A |
| Poles | 3P, 4P |
| Breaking Capacity (Icu) | 25 kA / 36 kA @ 415V AC |
| Trip Unit | Thermal-magnetic (TMD) |
| Operating Voltage | Up to 690V AC |
| Frequency | 50/60 Hz |
| Operating Temperature | -25°C to +70°C |
| Standard | IEC 60947-2 |
| Mounting | Fixed / Plug-in / Withdrawable |
| Protection Degree | IP40 (front face) |
Key Features
- ✓Adjustable overload (Ir) and short-circuit (Im) settings on TMD trip unit
- ✓Compact design with high breaking capacity — reduced panel footprint
- ✓Compatible with rotary handle, motor mechanism and auxiliary contacts
- ✓Available in fixed, plug-in and withdrawable versions
- ✓Suitable for use as both a main incoming device and feeder breaker
Application Areas
ABB Tmax XT Series MCCB
| Rated Current | 16A to 1000A |
| Poles | 3P, 4P |
| Breaking Capacity (Icu) | Up to 200 kA @ 415V AC |
| Trip Unit | TMF, TMA (thermal-mag) / Ekip (electronic) |
| Operating Voltage | Up to 1000V AC / 1500V DC |
| Standard | IEC 60947-2 |
| Mounting | Fixed / Plug-in / Withdrawable |
| Operating Temperature | -25°C to +70°C |
| Frame Sizes | XT1 (160A), XT2 (160A), XT4 (250A), XT5 (630A), XT6 (800A), XT7 (1000A) |
Key Features
- ✓Highest breaking capacity in class — up to 200kA
- ✓DC rated versions available for solar and battery storage
- ✓Ekip electronic trip units with zone selective interlocking
- ✓Compact footprint enabling smaller panel dimensions
- ✓Rated up to 1000V AC for medium-voltage interface applications
Application Areas
Control Panels
3 Products
Motor Control Center (MCC) Panel
| Incoming Rating | Up to 6300A |
| Outgoing Feeders | DOL / Star-Delta / VFD starters |
| Bus Bar Material | Copper / Aluminium |
| Fault Level | To project specification |
| Voltage | 415V, 3-Phase, 50 Hz |
| Protection Degree | IP42 / IP54 |
| Form of Separation | To project specification |
| Standard | To project specification |
| Metering | Ammeter, Voltmeter, Energy Meter |
| Control Supply | 230V AC / 110V AC / 24V DC |
Key Features
- ✓Single-line diagram engineered to plant motor list
- ✓Draw-out type feeders for live maintenance capability
- ✓Interlocked bus-coupler for dual-supply redundancy
- ✓SCADA-ready with Modbus/Profibus communication option
Application Areas

Power Control Center (PCC) Panel
| Incoming Rating | Up to 6300A |
| Incoming Device | ACB / MCCB with motorized operation |
| Outgoing Feeders | MCCBs / ACBs up to 1600A |
| Bus Bar Fault Level | To project specification |
| Voltage | 415V, 3-Phase, 50 Hz |
| Protection | Overcurrent, Earth Fault, Differential |
| Metering | Digital energy meter, PF meter, MD indicator |
| Standard | To project specification |
| Protection Degree | IP42 / IP54 |
Key Features
- ✓Main incoming Air Circuit Breaker with motorized operation
- ✓Comprehensive power metering — kWh, kVAh, PF, MD
- ✓Bus coupler arrangement for dual-supply operation
- ✓Generator changeover provision with auto-transfer scheme
- ✓Profibus/Modbus output for SCADA integration
Application Areas

Power Distribution Panel (PDB)
| Incoming Rating | Up to 400A |
| Incoming Device | MCCB / Isolator |
| Outgoing Devices | MCBs (1P, 2P, 3P, 4P) |
| No. of Outgoing Ways | 4 to 72 ways |
| Voltage | 240/415V AC |
| Protection | Overcurrent, ELCB (optional) |
| Enclosure | Sheet steel, powder-coated |
| Protection Degree | IP41 / IP54 |
| Standard | To project specification |
Key Features
- ✓Modular MCB design for easy addition of future circuits
- ✓ELCB / RCD earth-leakage protection (optional)
- ✓Cable management and labeling for organized wiring
- ✓Available in surface mount and flush mount versions
- ✓Fully wired and tested before dispatch
Application Areas
Bus Bars & Energy Meters
1 ProductSchneider PowerLogic PM5100 Energy Meter
| Measured Parameters | V, I, kW, kVAr, kVA, PF, Hz, kWh, kVArh |
| Accuracy Class | Class 0.5S (IEC 62053-22) |
| Current Input | 1A or 5A CT secondary |
| Voltage Input | 110V–400V AC (direct / VT) |
| Frequency | 45–65 Hz |
| Display | Backlit LCD, 4-line |
| Communication | Modbus RTU (RS-485) |
| Digital I/O | 2 Digital Inputs, 2 Relay Outputs |
| Protection Degree | IP54 (front face) |
| Standard | IEC 62053-22 |
Key Features
- ✓Class 0.5S accuracy (IEC 62053-22)
- ✓Full harmonic analysis up to 31st harmonic (PM5300/PM5500)
- ✓Modbus RTU for seamless SCADA and BMS integration
- ✓Demand monitoring with programmable interval
- ✓Min/Max recording with timestamp for energy auditing
Application Areas
PLCs — Programmable Logic Controllers
4 ProductsSiemens SIMATIC S7-1200 PLC
| CPU Types | CPU 1211C, 1212C, 1214C, 1215C, 1217C |
| Onboard DI/DO | 6 DI / 4 DO to 14 DI / 10 DO (CPU dependent) |
| Onboard AI/AO | 2 AI / — to 2 AI / 2 AO (CPU dependent) |
| Work Memory | 75KB to 150KB (CPU dependent) |
| Program Memory | 1MB to 4MB Flash |
| Communication | PROFINET (1 port), Point-to-Point, USS, Modbus |
| Programming SW | STEP 7 (TIA Portal V13+) |
| Motion Control | Up to 8 axes (CPU 1215C/1217C) |
| Supply Voltage | 24V DC / 120-240V AC |
| Operating Temp | 0°C to +55°C |
Key Features
- ✓Integrated PROFINET port for direct HMI and SCADA communication
- ✓Onboard motion control for up to 8 servo/stepper axes
- ✓Expandable with up to 8 signal modules and 3 communication modules
- ✓TIA Portal programming — single software for PLC, HMI and drives
- ✓Integrated web server for remote monitoring without HMI
- ✓OPC-UA server built-in (CPU 1215C/1217C) for Industry 4.0
Application Areas

Siemens SIMATIC S7-1500 PLC
| CPU Types | CPU 1511, 1513, 1515, 1516, 1517, 1518 |
| Bit Processing Speed | 1 ns (CPU 1518) |
| Work Memory | 150KB to 60MB (CPU dependent) |
| Max. I/O Modules | Up to 32 modules per rack |
| Communication | PROFINET, PROFIBUS DP, Industrial Ethernet |
| Integrated Display | Yes — 3.3" TFT (all CPUs) |
| Motion Control | Up to 128 axes (CPU 1517/1518) |
| Safety | F-CPU variants — up to SIL 3 / PL e (per Siemens) |
| Redundancy | R/H CPU variants for hot-standby redundancy |
| Operating Temp | 0°C to +60°C |
Key Features
- ✓Fastest S7 family — 1 nanosecond bit processing on CPU 1518
- ✓Integrated front display for on-site diagnostics without laptop
- ✓Fail-safe F-CPU variants certified for safety mode up to SIL 3 / PL e (per Siemens)
- ✓Hot-standby redundant R/H CPUs for critical continuous processes
- ✓MindSphere and OPC-UA connectivity for cloud data integration
- ✓Trace function for high-speed data recording and commissioning
Application Areas
Schneider Electric Modicon M221 PLC
| Onboard DI/DO | 16 to 40 I/O (model dependent) |
| Analogue I/O | Via expansion modules TM3 |
| Program Memory | 512KB |
| Communication | Ethernet, USB Mini-B, Serial (RS-232/RS-485) |
| Protocols Supported | Modbus TCP, Modbus RTU, EtherNet/IP |
| Programming SW | EcoStruxure Machine Expert — Basic |
| Expansion | Up to 14 TM3 expansion modules |
| Supply Voltage | 24V DC / 100-240V AC |
| Operating Temp | 0°C to +55°C |
| Protection Degree | IP20 |
Key Features
- ✓Integrated Ethernet with Modbus TCP for fast commissioning
- ✓SD card slot for program backup, data logging and remote updates
- ✓Fast counting inputs — up to 100 kHz for encoder feedback
- ✓PTO outputs for stepper/servo open-loop positioning
- ✓Compatible with Magelis HMIs via Ethernet or serial link
Application Areas
Schneider Electric Modicon M340 PLC
| Max. I/O Points | Up to 1024 DI/DO + 256 AI/AO |
| Program Memory | Up to 8MB |
| Communication | Ethernet (Modbus TCP, EtherNet/IP), Modbus RTU |
| Optional Buses | PROFIBUS DP Master/Slave, CANopen, AS-Interface |
| Programming SW | Unity Pro / EcoStruxure Control Expert |
| Redundancy | Available (Hot Standby) |
| Operating Temp | 0°C to +60°C |
| Supply Voltage | 24V DC / 100-240V AC (PSU module) |
| Rack Size | 4, 8, 12 slot racks |
Key Features
- ✓Multi-bus master capability — PROFIBUS and CANopen simultaneously
- ✓Hot-standby redundancy for critical process applications
- ✓Conformal coated versions for harsh environment installations
- ✓IEC 61131-3 programming in LD, FBD, IL, ST and SFC
- ✓Broad I/O module range — temperature, counter, weighing, motion
Application Areas
VFDs — Variable Frequency Drives
3 ProductsSiemens SINAMICS G120 Variable Frequency Drive
| Power Range | 0.37 kW to 250 kW |
| Input Voltage | 3-Phase 380–480V AC (±10%) |
| Output Frequency | 0 Hz to 550 Hz |
| Control Modes | V/f, Vector (sensorless / encoder), Servo |
| Control Units | CU230P-2, CU240B-2, CU240E-2, CU250S-2 |
| Communication | PROFINET, PROFIBUS DP, Modbus RTU, USS |
| Protection Degree | IP20 (PM240-2) / IP55 (PM240P-2) |
| Overload Capacity | 150% for 60 sec (High Overload) |
| Operating Temp | -10°C to +55°C |
Key Features
- ✓Modular Power Module + Control Unit — mix and match for application
- ✓Energy-saving V/f mode with ECO function for pumps and fans
- ✓Integrated STO (Safe Torque Off) safety function
- ✓PROFINET connectivity for direct TIA Portal integration
- ✓Built-in EMC filter (Class C2) — no external filter required
- ✓IP55 outdoor version available for outdoor pump stations
Application Areas
Schneider Electric Altivar ATV320 / ATV630 VFD
| Power Range | 0.18 kW to 800 kW |
| Input Voltage | 1-Phase 200-240V / 3-Phase 380-480V AC |
| Output Frequency | 0.1 Hz to 599 Hz |
| Control Modes | V/f, Sensorless Flux Vector, Closed-loop Vector |
| Communication | Modbus RTU, CANopen, EtherNet/IP, PROFIBUS (option) |
| Protection Degree | IP21 / IP55 (ATV630/ATV930) |
| Overload Capacity | 110% / 150% for 60 sec |
| Operating Temp | -10°C to +50°C |
| Display | 7-segment / Graphic LCD (ATV630) |
Key Features
- ✓PID controller built-in for pressure and flow process control
- ✓Pump-specific functions — multi-motor control, anti-jam, de-scaling
- ✓Energy dashboard on ATV630 — real-time kWh monitoring
- ✓STO + SS1 safety functions (ATV320)
- ✓Conformal coated PCBs — suitable for humid and corrosive environments
Application Areas

ABB ACS580 General Purpose VFD
| Power Range | 0.75 kW to 250 kW |
| Input Voltage | 3-Phase 380–480V AC (±10%) |
| Control Modes | Scalar (V/Hz), Vector (DTC) |
| Built-in Features | EMC filter, Brake chopper, Modbus RTU |
| Communication Options | PROFIBUS DP, PROFINET, EtherNet/IP, CANopen |
| Protection Degree | IP21 / IP55 options |
| Overload Capacity | 150% for 60 sec |
| Operating Temp | -15°C to +50°C (standard) |
| Assistant Panel | Graphical panel with assistant texts |
| Approvals | CE / UL / cUL (per ABB) |
Key Features
- ✓Direct Torque Control (DTC) — fastest torque response without encoder
- ✓Graphical assistant control panel — guides user through commissioning
- ✓All main features built-in — no expensive option modules needed
- ✓Flexible cooling — ULH-type allows cool air from outside cabinet
- ✓ABB Ability connectivity for cloud-based condition monitoring
Application Areas
HMIs — Human-Machine Interfaces
3 ProductsSiemens SIMATIC KTP700 Basic HMI Panel
| Display Size | 7" widescreen TFT (KTP700) |
| Resolution | 800 × 480 pixels |
| Colours | 65536 colours |
| Touch Type | Resistive touch + 8 function keys |
| Communication | PROFINET (1 port, RJ45) |
| Protocols | S7-1200/1500, S7-300/400, Modbus TCP |
| Configuration SW | WinCC (TIA Portal) V13+ |
| Memory | 10MB user memory, MicroSD card slot |
| Supply Voltage | 24V DC |
| Protection Degree | IP65 (front face) |
Key Features
- ✓IP65 front face — dust and jet-water proof for factory environment
- ✓Seamless TIA Portal integration — single project for PLC + HMI
- ✓8 physical function keys for reliable operator action in gloved hands
- ✓MicroSD slot for recipe storage and data logging
- ✓Multi-language support — English, Hindi and regional languages
Application Areas
Siemens SIMATIC TP1200 Comfort Panel
| Display Size | 12.1" widescreen TFT |
| Resolution | 1280 × 800 pixels |
| Colours | 16.7 million colours |
| Touch Type | Capacitive multi-touch (10-point) |
| Communication | PROFINET (2 ports), PROFIBUS DP, RS-422/485 |
| Protocols | S7-1200/1500, S7-300/400, Modbus, OPC-UA |
| User Memory | 64MB + MicroSD / USB expansion |
| Scripting | VBScript / JavaScript |
| Supply Voltage | 24V DC |
| Protection Degree | IP65 (front face) |
Key Features
- ✓Capacitive 10-point multi-touch — intuitive gesture control
- ✓Dual-channel: PROFINET + PROFIBUS simultaneously
- ✓OPC-UA server for direct connection to SCADA or MES systems
- ✓Built-in web browser and PDF viewer for documentation access
- ✓High-speed process value logging with timestamp resolution <1ms
Application Areas
Schneider Electric Magelis GTU HMI Panel
| Display Size Range | 3.5" to 15" (model dependent) |
| Resolution | 320×240 to 1024×768 pixels |
| Touch Type | Resistive / Capacitive (model dependent) |
| Communication | Ethernet (RJ45), RS-232, RS-485, USB |
| Protocols Supported | Modbus RTU/TCP, EtherNet/IP, PROFIBUS (option) |
| Configuration SW | Vijeo Designer 6.x |
| User Memory | 64MB to 512MB (model dependent) |
| Supply Voltage | 24V DC |
| Protection Degree | IP65 (front face) |
| Operating Temp | 0°C to +55°C |
Key Features
- ✓Wide range of screen sizes for machine or panel integration
- ✓Multi-vendor protocol support — connects to non-Schneider PLCs
- ✓Vijeo Designer recipe and data logging functions built-in
- ✓Sunlight-readable versions available for outdoor kiosks
- ✓FTP/SMTP for automated alarm email notification
Application Areas
Moulded Case Circuit Breakers (MCCBs)
2 ProductsSchneider Electric EasyPact EZC MCCB
| Rated Current | 16A to 400A |
| Poles | 3P, 4P |
| Breaking Capacity | 25 kA / 36 kA @ 415V AC |
| Trip Unit | Thermal-Magnetic (TMD) |
| Operating Voltage | Up to 690V AC |
| Frequency | 50/60 Hz |
| Frame Sizes | EZC100, EZC250, EZC400 |
| Standard | IEC 60947-2 |
| Protection Class | IP40 (front face) |
| Mounting | Fixed, Plug-in, Withdrawable |
Key Features
- ✓Adjustable thermal and magnetic trip settings
- ✓Multiple frame sizes for system flexibility
- ✓Front-face accessories: shunt trip, undervoltage, aux contacts
- ✓Available in fixed, plug-in, and withdrawable versions
- ✓Padlockable handle for lockout/tagout
Application Areas
ABB Tmax T Series MCCB
| Rated Current | 16A to 1600A |
| Poles | 3P, 4P |
| Breaking Capacity | 16 kA to 200 kA depending on series |
| Trip Unit | TMD (Thermal-Magnetic) / Ekip (Electronic) |
| Operating Voltage | Up to 1000V AC |
| Frame Sizes | T1(25A), T2(160A), T3(250A), T4(320A), T5(630A), T6(1600A) |
| Standard | IEC 60947-2 |
| Selectivity | Full selectivity up to T6 |
| Mounting | Fixed, Plug-in, Drawout, Rear Connection |
| Communication | Ekip units: Modbus, Profibus, Ethernet |
Key Features
- ✓Widest range: 16A to 1600A in one consistent product family
- ✓Ekip electronic trip units with built-in communication interfaces
- ✓Full selectivity between upstream and downstream breakers
- ✓Energy-limiting technology reduces let-through energy
- ✓Drawout version enables live changeout without power shutdown
- ✓IoT-ready with Ekip Connect for remote monitoring
Application Areas
Control Panels
2 Products
Motor Control Center (MCC) Panel
| Construction | Single / Double Front, Floor Standing |
| Bus Bar | Copper, 415V, 3P+N+E |
| Incomer | ACB / MCCB (as specified) |
| Outgoing Feeders | DOL / Star-Delta / VFD Starters |
| Metering | Ammeter, Voltmeter, Power Meter |
| Protection | Overload Relay, Earth Fault Relay |
| Control Voltage | 415V / 230V / 110V AC or 24V DC |
| IP Rating | IP42 / IP54 / IP65 (as required) |
| Finish | Powder Coated, RAL 7035 standard |
| Standards | To project specification |
Key Features
- ✓Custom designed to customer single-line diagram specifications
- ✓All components sourced from our supply-partner brands — fully traceable
- ✓Factory tested before dispatch — FAT documentation provided
- ✓Available with VFD feeder drawers for energy-efficient motor control
- ✓SCADA/PLC interfacing provisions on request
Application Areas

Power Control Center (PCC) Panel
| Construction | Double Front, Floor Standing, Extensible |
| Incomer | ACB up to 6300A |
| Bus Bar Rating | 800A to 6300A (Copper) |
| Outgoing | MCCB / ACB Feeders |
| Sections | Incomer + Bus Coupler + Outgoing |
| Metering | Multifunction Power Meter, CT/PT metering |
| Control Voltage | 110V AC / 24V DC (trip coil) |
| IP Rating | IP42 / IP54 |
| Standards | To project specification |
| Protection Relays | Overcurrent, Earth Fault, Differential (optional) |
Key Features
- ✓Main incomer ACBs with motorized operation for remote control
- ✓Bus coupler for parallel operation of two incomers
- ✓Integrated multifunction power meter for energy monitoring
- ✓Provisions for generator synchronization panel interface
Application Areas
Bus Bars & Energy Meters
1 ProductSchneider Electric PowerLogic PM5100 Energy Meter
| Accuracy Class | Class 0.5S (IEC 62053-22) |
| Measurements | V, I, kW, kVAR, kVA, PF, Hz, kWh, kVARh |
| Voltage Input | 57.7 to 400V L-N (up to 690V with VT) |
| Current Input | 1A or 5A secondary (via CT) |
| Display | Backlit LCD, 8-line |
| Communication | Modbus RTU (RS485) |
| Demand Monitoring | kW, kVAR, kVA demand + peak demand |
| Mounting | DIN Rail or Panel Cutout (92×92mm) |
| Auxiliary Supply | 100–415V AC or 24V DC |
| Standard | IEC 62053 / IEC 61557-12 |
Key Features
- ✓Class 0.5S accuracy (IEC 62053-22)
- ✓Complete power quality measurements including harmonics (PM5300+)
- ✓Modbus RTU for integration with SCADA and energy management systems
- ✓Min/Max demand logging with timestamp
- ✓Multi-tariff energy recording for time-of-use billing
Application Areas
PLCs — Programmable Logic Controllers
4 ProductsSiemens SIMATIC S7-1200 PLC
| CPU Variants | 1211C, 1212C, 1214C, 1215C, 1217C |
| Digital I/O | 6 DI / 4 DO to 14 DI / 10 DO (on-board) |
| Analog I/O | 2 AI standard (up to 9 AI with signal boards) |
| Work Memory | 50KB to 150KB (CPU dependent) |
| Communication | PROFINET (1x or 2x port), point-to-point |
| Programming | TIA Portal V15.1 and above (LAD, FBD, STL, SCL, GRAPH) |
| Supply Voltage | 24V DC / 120-240V AC |
| Output Types | Relay / Transistor (DC) |
| Expansion | Signal Modules, Signal Boards, Communication Modules |
| Operating Temp. | 0°C to +55°C (horizontal), 0°C to +45°C (vertical) |
Key Features
- ✓Integrated PROFINET for direct HMI and network connectivity
- ✓Built-in motion control for up to 4 axes (S7-1215C / 1217C)
- ✓Onboard signal board slot for analog I/O expansion without extra modules
- ✓TIA Portal integration for unified programming, HMI, and drives
- ✓HSC (High-Speed Counter) up to 1MHz for encoder feedback
- ✓Fail-safe versions (S7-1200F) available for safety applications
Application Areas

Siemens SIMATIC S7-1500 PLC
| CPU Variants | 1511 to 1518 (Standard, Advanced, Technology) |
| Work Memory | 150KB to 60MB (CPU dependent) |
| Max I/O | Up to 8192 digital + 2048 analog I/O points |
| Cycle Time | from 1ms (CPU 1511) to 0.016ms bit (CPU 1518) |
| Communication | PROFINET IRT, PROFIBUS, OPC UA, Industrial Ethernet |
| Motion Control | Up to 128 axes (Technology CPUs) |
| Programming | TIA Portal V16+ (LAD, FBD, STL, SCL, GRAPH, CFC) |
| Cybersecurity | Integrated access protection, integrity check |
| Display | Integrated CPU display for diagnostics |
| Safety | F-CPU variants (1511F to 1518F) — up to SIL 3 / PL e (per Siemens) |
Key Features
- ✓Integrated display for on-site diagnostics without laptop
- ✓OPC UA server for Industry 4.0 and MES/ERP connectivity
- ✓PROFINET IRT for isochronous real-time motion synchronization
- ✓F-CPU variants certified for safety mode up to SIL 3 / PL e (per Siemens)
- ✓Redundant CPU (S7-1500R/H) for high-availability systems
- ✓Built-in cybersecurity with program integrity verification
Application Areas
Schneider Electric Modicon M221 Logic Controller
| Digital I/O | 16 to 40 DI/DO (base unit) |
| Analog I/O | Via TM3 expansion modules |
| Work Memory | 256KB |
| Communication | Ethernet (Modbus TCP), Serial (Modbus RTU / ASCII) |
| Programming | EcoStruxure Machine Expert — Basic (LD, IL, SFC, FBD) |
| Supply Voltage | 24V DC / 100-240V AC |
| Output Types | Relay / Transistor |
| High-Speed Counter | Up to 200kHz (single phase) |
| SD Card Slot | Yes — for program backup and data logging |
| Operating Temp. | 0°C to +55°C |
Key Features
- ✓Built-in Ethernet port for direct HMI and SCADA connection
- ✓SD card slot for program storage, recipe data, and event logs
- ✓EcoStruxure Machine Expert free software — no license cost
- ✓USB mini-B port for direct programming without network
- ✓Compact size — mounts directly in small machine panels
Application Areas
Schneider Electric Modicon M340 PAC
| Max I/O | Up to 1024 DI/DO, 256 AI/AO |
| Work Memory | Up to 8MB |
| Communication | Ethernet, PROFIBUS DP, CANopen, Modbus |
| Programming | Unity Pro / EcoStruxure Control Expert (LD, FBD, SFC, ST, IL) |
| Backplane | 4 to 12 slots (expandable) |
| Redundancy | Hot standby CPU redundancy available |
| Supply | 24V DC or 100-240V AC backplane power |
| Operating Temp. | 0°C to +60°C |
| Programming languages | IEC 61131-3 languages (LD, FBD, SFC, ST, IL) |
| Cybersecurity | User access control, application password protection |
Key Features
- ✓Hot standby redundancy for high-availability process control
- ✓PROFIBUS DP master for legacy instrument integration
- ✓CANopen for distributed I/O and drive communication
- ✓Extensive diagnostics via embedded web server
Application Areas
VFDs — Variable Frequency Drives
3 ProductsSiemens SINAMICS G120 Variable Frequency Drive
| Power Range | 0.37 kW to 250 kW |
| Input Voltage | 200–240V (1-phase), 380–480V (3-phase) |
| Output Frequency | 0 to 550 Hz |
| Control Mode | V/f, Vector Control (sensorless/encoder), Servo |
| Communication | PROFINET, PROFIBUS, Modbus RTU, EtherNet/IP |
| Safety | STO (Safe Torque Off) — SIL 2 / PL d (per Siemens) |
| Protection | IP20 (standard), IP55 (SINAMICS G120C compact) |
| Braking | Dynamic braking resistor / Regenerative (PM250) |
| Energy Saving | Energy saving mode + energy meter built-in |
Key Features
- ✓Modular Control + Power Module — replace one without rewiring
- ✓Integrated STO safety function
- ✓Built-in energy meter for real-time consumption monitoring
- ✓PROFINET / PROFIBUS for direct Siemens PLC integration
- ✓PM250 regenerative module feeds braking energy back to grid
- ✓SINAMICS G120C compact version for space-constrained panels
Application Areas
Schneider Electric Altivar ATV320 Variable Speed Drive
| Power Range | 0.18 kW to 15 kW (single phase: 0.18–2.2kW) |
| Input Voltage | 200–240V (1-phase), 380–500V (3-phase) |
| Output Frequency | 0.5 to 500 Hz |
| Control Mode | V/f (2-point, 5-point), Sensorless Vector, Flux Vector |
| Communication | CANopen, Modbus RTU, Ethernet Modbus TCP, PROFIBUS (option) |
| Safety | Integrated STO safety function (ratings per Schneider Electric documentation) |
| Protection | IP20 (booktype), IP21 / IP55 (compact) |
| Built-in Features | EMC filter, dynamic braking transistor, PID controller |
| Standards | IEC 61800-5-2 (safety functions) |
| Display | Integrated display + removable keypad |
Key Features
- ✓Built-in EMC filter — no external filter required for most installations
- ✓Integrated dynamic braking transistor for quick deceleration
- ✓Built-in PID controller for closed-loop pressure/flow control
- ✓Single-phase input versions for locations without 3-phase supply
- ✓Commissioning wizard on integrated keypad for quick setup
Application Areas
ABB ACS550 Industrial Drive
| Power Range | 0.75 kW to 355 kW |
| Input Voltage | 208–240V, 380–480V, 500–600V (3-phase) |
| Output Frequency | 0 to 500 Hz |
| Control Mode | Scalar (V/f), Vector (DTC — Direct Torque Control) |
| Communication | Modbus RTU, PROFIBUS, CANopen, DeviceNet (option modules) |
| Protection | IP21 / UL Type 1 standard; IP54 optional |
| Built-in Features | EMC filter, choke, PID, fire mode, PFC pump control |
| Energy Saving | Energy optimizer + kWh meter |
| Keypad | Assistant Control Panel with parameter copy function |
Key Features
- ✓ABB's DTC (Direct Torque Control) for superior motor control accuracy
- ✓Built-in PFC (Pump and Fan Control) macro for rapid commissioning
- ✓Fire mode — drive continues operating even in alarm/fault conditions for emergency ventilation
- ✓Energy optimizer reduces motor magnetizing current at partial loads
- ✓Parameter copy via keypad for fast commissioning of multiple drives
Application Areas
HMIs — Human-Machine Interfaces
3 ProductsSiemens SIMATIC KTP700 Basic Panel HMI
| Display Size | 7" widescreen TFT (800×480 pixels) |
| Colors | 65536 colors (16-bit) |
| Operation | Touch + 8 programmable function keys |
| Communication | PROFINET (1x RJ45), MPI/PROFIBUS (optional) |
| Memory | 10MB user memory |
| Engineering | TIA Portal WinCC Basic / Comfort |
| Alarms | Up to 512 alarm messages |
| Tags | Up to 500 process tags (KTP700 Basic) |
| Supply Voltage | 24V DC |
| Protection | IP65 (front panel), IP20 (rear) |
Key Features
- ✓IP65 front panel — splash and dust proof for plant floor installation
- ✓Physical function keys for operator actions that require tactile confirmation
- ✓PROFINET connectivity for direct S7-1200 / S7-1500 integration
- ✓TIA Portal configuration — same tool as PLC for seamless engineering
- ✓Available in 7", 9", and 12" display sizes
Application Areas
Siemens SIMATIC TP1200 Comfort Panel HMI
| Display Size | 12.1" widescreen TFT (1280×800 pixels) |
| Colors | 16 million colors (24-bit) |
| Operation | Multi-touch (10-point) |
| Communication | PROFINET (2x RJ45), MPI/PROFIBUS, USB, SD Card |
| Memory | 24MB user memory |
| Engineering | TIA Portal WinCC Comfort |
| Alarms | Up to 32768 alarm classes |
| PLC Connections | Up to 6 simultaneous |
| Data Logging | SD card / USB up to 32GB |
| Supply Voltage | 24V DC |
Key Features
- ✓Multi-touch for intuitive gestures (zoom, swipe, pinch) on trends
- ✓Recipe management for product changeovers in pharma and food lines
- ✓Data logging to SD/USB for historical analysis
- ✓VPN client for remote diagnostics via secure internet connection
- ✓OPC UA client for connectivity to third-party systems
Application Areas
Schneider Electric Magelis GTU Advanced HMI Panel
| Display Sizes | 10", 12", 15" (widescreen TFT) |
| Resolution | 1024×600 (10"), 1280×800 (12"), 1280×800 (15") |
| Colors | 16 million colors (24-bit TFT) |
| Processor | 1GHz ARM Cortex-A8 |
| RAM / Flash | 512MB RAM / 512MB Flash |
| Communication | Ethernet (2×RJ45), Serial (COM1/COM2), USB, SD Card |
| Protocols | Modbus TCP/RTU, EtherNet/IP, PROFIBUS, CAN, Uni-Telway |
| Engineering Tool | Vijeo Designer (free, offline) |
| Supply Voltage | 24V DC |
| Protection | IP66 (front panel) |
Key Features
- ✓IP66 front panel — one of the highest protection ratings in its class
- ✓Multi-protocol support — connects to PLCs from multiple vendors simultaneously
- ✓Vijeo Designer scripting for advanced custom logic within HMI
- ✓VNC server for remote viewing from PC or tablet
- ✓Dual Ethernet ports for network segmentation (plant + office networks)
Application Areas
Contactors & Relays
2 ProductsSchneider Electric TeSys D Series Contactor
| Current Range (AC-3) | 9A to 150A |
| Motor Power (AC-3, 415V) | 4 kW to 75 kW |
| Poles | 3P main + 1 NO auxiliary (standard) |
| Coil Voltage | 24V, 48V, 110V, 220V, 415V AC/DC options |
| Operating Frequency | Up to 3600 operations/hour (AC-3) |
| Mechanical Endurance | Up to 30 million operations |
| Mounting | DIN Rail or screw |
| Standards | IEC/EN 60947-4-1 |
| Accessories | Auxiliary blocks, timer modules, surge suppressors, mechanical interlocks |
| Reversing Contactors | LC2D (factory-assembled reversing pair) |
Key Features
- ✓Consistent front-face dimensions across LC1D09 to LC1D65 for easy panel replacement
- ✓Wide coil voltage range — 24V DC to 415V AC for any control circuit
- ✓Clip-on auxiliary contact blocks — no tools required
- ✓Mechanical interlock available for forward/reverse (DOL reversing)
- ✓Up to 30 million mechanical operations — industry-leading longevity
Application Areas
Schneider Electric Zelio Logic Smart Relay
| I/O Count | 10 to 40 I/O (model dependent) |
| Digital Inputs | 6 to 24 DI (with analogue variants) |
| Relay Outputs | 4 to 16 relay outputs |
| Display | Backlit LCD with keypad (Smart models) |
| Programming | Ladder (LD) or Function Block (FBD) — Zelio Soft 2 |
| Communication | RS485 Modbus RTU (extended models) |
| Supply Voltage | 24V DC / 100-240V AC |
| Clock / Calendar | Built-in real-time clock (24h / weekly / annual programs) |
| Memory | Cartridge-based program storage |
| Timers / Counters | Up to 32 timers, 16 counters |
Key Features
- ✓Built-in real-time clock for time-based scheduling without external timer
- ✓No PC required for basic programming — done via front-panel keypad
- ✓Removable memory cartridge for quick field replacement
- ✓Zelio Soft 2 free software for simulation before panel installation
- ✓Modbus RTU communication for SCADA integration
Application Areas
Motor Starters
1 ProductSchneider Electric Star-Delta Motor Starter
| Motor Power Range | 18.5 kW to 250 kW |
| Supply Voltage | 415V AC, 3-phase |
| Starting Current | 33% of DOL starting current |
| Contactor Set | 3× TeSys D (Main, Star, Delta) |
| Timer Type | Electronic timer relay (0.3s to 300s range) |
| Overload Relay | Schneider LRD thermal overload relay |
| Control Voltage | 24V DC / 110V / 230V / 415V AC |
| Enclosure | GI powder-coated, IP54 standard |
| Transition | Open transition (standard) / Closed transition (optional) |
Key Features
- ✓Reduces starting current to 33%
- ✓Electronic timer gives precise, repeatable star-to-delta changeover timing
- ✓Mechanical interlock between Star and Delta contactors prevents simultaneous closure
- ✓Factory wired and tested with wiring diagram on door
- ✓Closed-transition option available to eliminate voltage dip during changeover
Application Areas