| Rated Current | 1A to 63A |
| Poles | 1P, 2P, 3P, 4P |
| Breaking Capacity | 6 kA (IEC 60898) |
| Tripping Characteristic | B, C, D curves |
| Operating Voltage | 230/400V AC |
| Frequency | 50/60 Hz |
| Operating Temperature | -25ยฐC to +70ยฐC |
| Standard | IEC 60898-1 / EN 60898-1 |
| Mounting | DIN Rail (TH35) |
| Protection Degree | IP20 |
| Rated Current | 0.5A to 63A |
| Poles | 1P, 2P, 3P, 4P |
| Breaking Capacity | 10 kA (IEC 60898) |
| Tripping Characteristic | B, C curves |
| Operating Voltage | 240/415V AC, 125V DC |
| Frequency | 50 Hz |
| Operating Temperature | -20ยฐC to +60ยฐC |
| Standard | IS 8828 / IEC 60898 |
| Mounting | DIN Rail (TH35) |
| Protection Degree | IP20 |
| Rated Current | 0.5A to 63A |
| Poles | 1P, 2P, 3P, 4P |
| Breaking Capacity | 6 kA / 10 kA options |
| Tripping Characteristic | B, C, D curves |
| Operating Voltage | 230/400V AC |
| Frequency | 50/60 Hz |
| Operating Temperature | -25ยฐC to +55ยฐC |
| Standard | IEC/EN 60898-1 |
| Mounting | DIN Rail (TH35) |
| Width per Pole | 17.5 mm |
| Rated Current | 16A to 630A |
| Poles | 3P, 4P |
| Breaking Capacity (Icu) | 25 kA to 70 kA at 415V |
| Trip Unit | Thermal-magnetic (TM-D) |
| Operating Voltage | Up to 690V AC |
| Frequency | 50/60 Hz |
| Frame Sizes | EZC100, EZC250, EZC400, EZC630 |
| Standard | IEC 60947-2 |
| Mounting | Fixed / Plug-in / Withdrawable |
| Protection Degree | IP40 (front face) |
| Rated Current | 16A to 400A |
| Poles | 3P, 4P |
| Breaking Capacity (Icu) | 35 kA to 65 kA at 415V |
| Trip Unit | Thermal-magnetic / Electronic (optional) |
| Operating Voltage | 415V AC (up to 690V for higher ratings) |
| Standard | IS 13947-2 / IEC 60947-2 |
| Mounting | Fixed / Draw-out |
| Terminal Type | Box / Lug terminals |
| Protection Degree | IP40 |
| Pollution Degree | 3 |
| Rated Current | 16A to 800A |
| Poles | 3P, 4P |
| Breaking Capacity (Icu) | Up to 200 kA at 415V |
| Trip Unit | TMD (thermal-magnetic) / PR221 (electronic) |
| Operating Voltage | Up to 690V AC |
| Frequency | 50/60 Hz |
| Standard | IEC 60947-2 |
| Mounting | Fixed / Plug-in / Withdrawable |
| Service Life (Electrical) | Up to 25,000 operations |
| Communication (optional) | Modbus RTU / Profibus |
| Rated Current | 16A (switches), 16A/32A (sockets) |
| Rated Voltage | 250V AC (switches), 415V AC (sockets) |
| Protection Degree | IP20 (surface), IP44 (industrial) |
| Switch Types | 1-way, 2-way, Intermediate, Bell-press |
| Socket Types | 2P+E, 3P+E, 3P+N+E |
| Standard | IEC 60669-1 / IS 3854 |
| Mounting | Flush / Surface / DIN rail |
| Operating Temperature | -5ยฐC to +40ยฐC |
| Rated Current | 16A to 125A |
| Rated Voltage | 240V / 415V AC |
| Protection Degree | IP44 / IP67 |
| Switch Types | DP, TP isolators; 1-way, 2-way |
| Socket Types | 2P+E (16A), 3P+E (32A), 3P+N+E (63A/125A) |
| Standard | IEC 60309, IS 1293 |
| Body Material | Glass-filled Nylon (GFN) |
| Interlock | Mechanical interlock on industrial sockets |
| Conductor | Annealed plain copper (Class 1 & 2) |
| Insulation | FR-PVC compound |
| Cross-Section | 0.5 sq mm to 400 sq mm |
| Voltage Rating | 1100V AC (IS 694) |
| Operating Temperature | -20ยฐC to +70ยฐC (conductor) |
| Flame Retardancy | As per IS 694 / IEC 60332-1 |
| Standard | IS 694 / IS 8130 |
| Colour Code | Red, Yellow, Blue, Black, Green/Yellow |
| Drum Length | 100m, 200m, 500m coils |
| Conductor | Annealed plain copper |
| Insulation | HFFR (Halogen-Free Flame Retardant) |
| Cross-Section | 0.5 sq mm to 300 sq mm |
| Voltage Rating | 1100V AC |
| Smoke Density | Max 60% (IEC 61034) |
| Halogen Content | <0.5% (IEC 60754-1) |
| Oxygen Index | >30% (IEC 60332-3) |
| Standard | IEC 60332-3 / IEC 61034 / IEC 60754 |
| Operating Temperature | -15ยฐC to +75ยฐC |
| Conductor | Stranded aluminium or copper |
| Insulation | XLPE (Cross-Linked Polyethylene) |
| Armour | Galvanised Steel Wire (SWA) |
| Outer Sheath | PVC ST2 / FRLS |
| Voltage Rating | 1.1kV / 3.3kV / 6.6kV / 11kV |
| Cross-Section | 16 sq mm to 630 sq mm |
| Cores | 1C, 2C, 3C, 3.5C, 4C |
| Max Operating Temp | 90ยฐC (conductor) |
| Standard | IS 7098 / IEC 60502 |
| Installation | Direct burial / Duct / Tray |
| Conductor | Stranded tinned copper (Class 5) |
| Insulation | PVC / FRLS |
| Shielding | Aluminium foil + drain wire (optional) |
| Cores | 2C to 61C |
| Cross-Section | 0.5 sq mm to 2.5 sq mm |
| Voltage Rating | 300/500V AC |
| Flexibility Class | Class 5 (highly flexible) |
| Standard | IS 1554 / IEC 60227 |
| Operating Temperature | -10ยฐC to +70ยฐC |
| Voltage | 415V AC, 3-phase, 50Hz |
| Incomer Rating | 100A to 3200A (as specified) |
| Busbar Material | Copper / Aluminium |
| Protection Degree | IP42 / IP54 (NEMA 12 optional) |
| Mounting | Floor-standing, cubicle type |
| Standard | IEC 61439-2 / IS 8623 |
| Starter Types | DOL, Star-Delta, Soft Starter, VFD |
| Protection Relays | Overload, Earth fault, Under/Over voltage |
| Metering | Ammeter, Voltmeter, Power meter (optional) |
| Communication | Modbus / Profibus (optional) |
| Voltage | 415V AC, 3-phase, 4-wire, 50Hz |
| Incomer Rating | 630A to 6300A |
| Breaker Type | ACB (Air Circuit Breaker) / MCCB |
| Busbar | Copper โ rated for 25kA to 85kA fault level |
| Protection Degree | IP42 / IP54 |
| Standard | IEC 61439-1 & 2 / IS 8623 |
| Metering | Multifunction energy meter, power analyser |
| Bus Configuration | Single / Double bus with coupler |
| Communication | Modbus RTU / Ethernet (optional) |
| Voltage | 415V / 240V AC |
| Incomer | MCCB 63A to 400A |
| Outgoing Ways | 8 to 36 ways (MCB) |
| MCB Rating | 6A to 63A |
| Protection Degree | IP43 / IP65 (outdoor) |
| Enclosure | Sheet steel / GRP (Glass Reinforced Plastic) |
| Busbar | Copper tinned, 63A to 400A rated |
| Mounting | Surface / Flush / Pole-top |
| Standard | IEC 61439 / IS 8623 |
| Measurement Accuracy | Class 0.5S (IEC 62053-22) |
| Voltage Input | Up to 690V L-L (direct) |
| Current Input | 1A or 5A (via CT) |
| Parameters Measured | V, I, kW, kVA, kVAR, PF, Hz, kWh, THD |
| Harmonics | Up to 31st harmonic |
| Display | Backlit LCD, 4-line |
| Communication | Modbus RTU (RS-485) / Ethernet (PM5310) |
| Digital Inputs/Outputs | 2 DI, 2 DO (relay) |
| Mounting | Panel cut-out 92 ร 92 mm |
| Standard | IEC 62053 / MID approved |
| Conductor Range | 0.5 sq mm to 35 sq mm |
| Rated Current | 6A to 125A (depending on size) |
| Rated Voltage | Up to 1000V AC |
| Connection Type | Screw / Spring clamp / Push-in |
| Mounting | DIN Rail EN 50022 (35mm) |
| Material | Polyamide PA6.6 (UL94 V0) |
| Protection Degree | IP20 |
| Standard | IEC 60947-7-1 / UL 508A |
| Colour Options | Grey, Blue (N), Green/Yellow (PE), Orange |
| Accessories | End stops, jumpers, markers, bridges |
| Rated Current | 25A to 5000A |
| Voltage | 415V / 690V AC, 3-phase |
| Conductor Material | Copper (KS/KT) / Aluminium (KN) |
| IP Rating | IP55 (KS), IP40 (KT/KN) |
| Short Circuit Withstand | Up to 100 kA (1 sec) |
| Tap-off Units | Every 0.5m along the run |
| Phases | 3P+N+PE (5 conductor) |
| Standard | IEC 61439-6 |
| Installation | Horizontal / Vertical / Overhead |
| CPU Variants | CPU 1211C to 1217C |
| Digital I/O (onboard) | 6 DI / 4 DO to 14 DI / 10 DO |
| Analog I/O (onboard) | 2 AI / 0 AO to 2 AI / 2 AO |
| Program Memory | 75 KB to 150 KB |
| Data Memory | 100 KB to 4 MB |
| Communication | PROFINET (1โ3 ports), RS-485 optional |
| Signal Modules | Up to 8 SM (I/O expansion) |
| Motion Control | Up to 4 axes (via TO technology objects) |
| Supply Voltage | 24V DC / 120-240V AC |
| Programming Software | TIA Portal V15/V16/V17/V19 |
| CPU Range | CPU 1511-1 PN to CPU 1518-4 PN/DP |
| Bit Performance | 1 ns to 60 ns per instruction |
| Work Memory | 150 KB to 60 MB |
| Communication | PROFINET (2โ3 ports), PROFIBUS DP |
| I/O Expansion | Via PROFINET / PROFIBUS ET 200 |
| Safety (F-CPU) | SIL 2 / PLe (IEC 62061 / ISO 13849) |
| Motion Control | Up to 128 axes |
| Display | Integrated TFT display on CPU (colour) |
| Cybersecurity | Access protection, copy protection, OPC UA |
| Programming | TIA Portal, LAD, FBD, SCL, STL, GRAPH |
| Digital I/O | 16 to 40 (onboard) |
| Analog I/O | 2 AI built-in (some variants) |
| Program Memory | 512 KB |
| Data Memory | 256 KB |
| Communication | Ethernet (Modbus TCP), RS-485, USB |
| High-Speed I/O | 4 HSC (100 kHz), 2 PTO (100 kHz) |
| Supply Voltage | 24V DC / 100-240V AC |
| Output Types | Relay / Transistor (NPN/PNP) |
| Programming | EcoStruxure Machine Expert Basic (LD, IL) |
| Expansion | Up to 7 I/O expansion modules |
| CPU Processing | 0.1 ยตs per boolean instruction |
| Program Memory | Up to 8 MB |
| I/O Capacity | Up to 1024 I/O (local + remote) |
| Communication | Ethernet, PROFIBUS DP, CANopen, Modbus |
| Rack Slots | 4 to 12 slot racks |
| Redundancy | Hot Standby CPU redundancy (optional) |
| Supply Voltage | 24V DC / 100-240V AC |
| Programming | EcoStruxure Control Expert (IEC 61131-3) |
| Operating Temperature | 0ยฐC to +60ยฐC |
| Power Range | 0.37 kW to 250 kW |
| Input Voltage | 200โ240V / 380โ480V / 500โ690V AC |
| Output Frequency | 0 to 550 Hz |
| Control Mode | V/f, Sensorless Vector, Closed-loop Vector |
| Communication | PROFINET, PROFIBUS, USS, Modbus RTU |
| Safety Functions | STO, SS1, SLS, SDI, SLA (IEC 62061 SIL 2) |
| Overload Capacity | 150% for 60 sec / 200% for 3 sec |
| Protection Degree | IP20 (chassis) / IP55 (SINAMICS G120C) |
| Braking | DC braking / Dynamic braking (with resistor) |
| Energy Savings | Energy-saving V/f mode for pumps & fans |
| Power Range | 0.18 kW to 15 kW |
| Input Voltage | 200โ240V 1ph/3ph / 380โ500V 3ph |
| Output Frequency | 0.5 to 500 Hz |
| Control Mode | V/f, Sensorless Flux Vector, Flux Vector |
| Communication | Modbus RTU, CANopen, PROFIBUS, EtherNet/IP |
| Safety | STO โ SIL 2 / PLd (IEC 62061 / ISO 13849) |
| Integrated EMC Filter | C1/C2 compliant (optional C3) |
| Overload | 170% for 60 sec (normal duty) |
| Protection Degree | IP20 / IP21 (with cover) |
| Braking Transistor | Built-in (up to 7.5 kW) |
| Power Range | 0.75 kW to 250 kW |
| Input Voltage | 380โ480V AC, 3-phase |
| Control Method | DTC (Direct Torque Control) / Scalar |
| Output Frequency | 0 to 500 Hz |
| Communication | Modbus RTU, EtherNet/IP, PROFIBUS, PROFINET |
| Built-in PLC | Yes โ for standalone pump/fan logic |
| Energy Optimiser | Built-in energy optimisation function |
| Protection Degree | IP21 / IP55 (frame R1โR9) |
| EMC Filter | C2 integrated (standard) |
| Overload | 110% continuous / 150% for 1 min |
| Display Size | 7" widescreen TFT |
| Resolution | 800 ร 480 pixels |
| Colour Depth | 64K colours |
| Touch Screen | Resistive touch + 8 function keys |
| Communication | PROFINET (Ethernet) |
| Compatible PLCs | SIMATIC S7-1200 / S7-1500 / S7-300/400 |
| Project Memory | 10 MB |
| Number of Tags | 800 power tags |
| Operating System | Windows CE 6.0 |
| Supply Voltage | 24V DC |
| Display Size | 12.1" widescreen TFT |
| Resolution | 1280 ร 800 pixels |
| Colour Depth | 16 million colours |
| Touch Type | Capacitive multi-touch (10-point) |
| Communication | PROFINET + PROFIBUS DP (dual) |
| USB Ports | 2 ร USB 2.0 Host |
| Project Memory | 24 MB (user memory) |
| Number of Tags | Unlimited (Comfort class) |
| Alarms | Up to 20,000 alarm events |
| Recipes | Up to 500 recipes, 1000 records each |
| Display Sizes | 3.5" / 5.7" / 7" / 10.4" / 15" |
| Resolution | 320ร240 to 1024ร768 pixels |
| Touch Type | Resistive analog touch |
| Communication | Ethernet, RS-232, RS-485, USB Host |
| Compatible PLCs | Modicon M221/M340/Premium/Quantum |
| Multi-Protocol | Modbus TCP, Uni-Telway, EtherNet/IP |
| Project Memory | Up to 128 MB (SD Card expandable) |
| Configuration | Vijeo Designer (free download) |
| Protection Degree | IP65 (front panel) |
| Supply Voltage | 24V DC |
| Rated Current (AC-3) | 9A to 95A |
| Motor Power (400V AC-3) | 4 kW to 45 kW |
| Poles | 3P (main) + 1NO+1NC (auxiliary) |
| Coil Voltage | 24V / 48V / 110V / 230V / 415V AC & DC |
| Rated Voltage | Up to 690V AC |
| Electrical Endurance | Up to 10 million operations (AC-3) |
| Standard | IEC 60947-4-1 / IS 13947-4-1 |
| Mounting | DIN Rail / Screw mounting |
| Operating Temperature | -40ยฐC to +60ยฐC |
| Rated Current (AC-3) | 12A to 65A |
| Motor Power (415V AC-3) | 5.5 kW to 30 kW |
| Poles | 3P + 1NO+1NC auxiliary |
| Coil Voltage | 24V / 110V / 230V / 415V AC |
| Rated Voltage | Up to 690V AC |
| Standard | IS 13947 / IEC 60947-4-1 |
| BIS Certification | Yes โ IS 13947 certified |
| Mounting | DIN Rail 35mm / Panel screw |
| Mechanical Life | 10 million operations |
| Digital Inputs | 10 to 40 (depending on model) |
| Digital Outputs | 6 to 24 (relay / transistor) |
| Analog Inputs | Up to 4 (0-10V / 4-20mA, some models) |
| Supply Voltage | 12V DC / 24V DC / 100-240V AC |
| Timers | Up to 32 (TON, TOF, TP, etc.) |
| Counters | Up to 16 (up/down, HSC) |
| Communication | Modbus RTU (SR2E / SR3 models) |
| Display | Built-in LCD (SR2 models) |
| Programming | Ladder (on-device) / Zelio Soft 2 (PC) |
| Standard | IEC 61131-3 |
| Motor Power Range | 0.37 kW to 22 kW (DOL) |
| Contactor Model | MNX 12 to MNX 40 |
| Overload Relay | MO Series โ adjustable range |
| Overload Setting | Continuously adjustable current dial |
| Trip Class | Class 10 / Class 20 |
| Phase Loss Sensitivity | Yes โ trips on single phasing |
| Reset | Manual / Auto reset |
| Supply Voltage | 415V AC, 3-phase, 50Hz |
| Standard | IEC 60947-4-1 / IS 13947-4-1 |
| Coil Voltage | 24V / 110V / 230V / 415V AC |
| Motor Power Range | 22 kW to 315 kW |
| Starting Current Reduction | Reduced to 33% of DOL starting current |
| Contactors Required | 3 ร TeSys D (Main, Star, Delta) |
| Timer | LAD8N10 pneumatic or electronic timer |
| Transition Time | Adjustable 3 to 30 seconds |
| Overload Relay | LRD series thermal overload |
| Interlocking | Electrical + mechanical interlock |
| Supply Voltage | 415V AC, 3-phase, 50Hz |
| Coil Voltage | 24V / 110V / 230V / 415V AC |
| Standard | IEC 60947-4-1 |
| Rated Current | 16A to 250A |
| Poles | 3P, 4P |
| Breaking Capacity (Icu) | 25 kA / 36 kA @ 415V AC |
| Trip Unit | Thermal-magnetic (TMD) |
| Operating Voltage | Up to 690V AC |
| Frequency | 50/60 Hz |
| Operating Temperature | -25ยฐC to +70ยฐC |
| Standard | IEC 60947-2 |
| Mounting | Fixed / Plug-in / Withdrawable |
| Protection Degree | IP40 (front face) |
| Rated Current | 16A to 630A |
| Poles | 3P, 4P |
| Breaking Capacity (Icu) | Up to 50 kA @ 415V AC |
| Trip Unit | Thermal-magnetic / Electronic (ETU) |
| Operating Voltage | 415V AC / 500V AC |
| Frequency | 50 Hz |
| Standard | IS 13947-2 / IEC 60947-2 |
| Mounting | Fixed / Draw-out |
| Operating Temperature | -10ยฐC to +55ยฐC |
| Short-Time Withstand (Icw) | Up to 50 kA / 1 sec |
| Rated Current | 16A to 1000A |
| Poles | 3P, 4P |
| Breaking Capacity (Icu) | Up to 200 kA @ 415V AC |
| Trip Unit | TMF, TMA (thermal-mag) / Ekip (electronic) |
| Operating Voltage | Up to 1000V AC / 1500V DC |
| Standard | IEC 60947-2 |
| Mounting | Fixed / Plug-in / Withdrawable |
| Operating Temperature | -25ยฐC to +70ยฐC |
| Frame Sizes | XT1 (160A), XT2 (160A), XT4 (250A), XT5 (630A), XT6 (800A), XT7 (1000A) |
| Rated Voltage | 250V AC |
| Rated Current | 6A, 10A, 16A, 20A |
| Switch Type | 1-way, 2-way, Intermediate |
| Socket Type | 2-pin, 3-pin (Indian/Universal) |
| Protection Degree | IP20 (with cover IP44) |
| Material | UV-stabilized polycarbonate |
| Operating Temperature | -5ยฐC to +40ยฐC |
| Standard | IS 3854 / IEC 60884 |
| Mounting | Modular (25mm / 50mm modules) |
| Colour | White, Graphite, Champagne |
| Rated Current | 16A, 32A, 63A, 125A |
| Rated Voltage | 110V, 230V, 400V AC |
| Poles | 2P+E, 3P+E, 3P+N+E |
| Protection Degree | IP44 / IP67 |
| Operating Temperature | -25ยฐC to +40ยฐC |
| Material | Polyamide (Nylon) โ halogen-free |
| Standard | IEC 60309-1 / EN 60309 |
| Cable Entry | Pg, Metric threads |
| Locking | Quarter-turn bayonet lock |
| Conductor Material | Electrolytic Copper (ETP) |
| Insulation | FR-PVC (Flame Retardant) |
| Voltage Grade | 1.1 kV |
| Conductor Sizes | 0.5 sq.mm to 400 sq.mm |
| No. of Cores | 1C, 2C, 3C, 3.5C, 4C |
| Temperature Rating | 70ยฐC (continuous), 160ยฐC (short circuit) |
| Flame Retardancy | IEC 60332-1 / IS 694 |
| Standard | IS 694 / IEC 60227 |
| Sheath Colour | Red, Yellow, Blue, Black, Green |
| Conductor Material | Electrolytic Copper (ETP) |
| Insulation | HFFR (Halogen-Free FR Compound) |
| Voltage Grade | 1.1 kV |
| Conductor Sizes | 1.0 sq.mm to 300 sq.mm |
| No. of Cores | 1C, 2C, 3C, 3.5C, 4C |
| Temperature Rating | 90ยฐC (continuous) |
| Smoke Density | โค60% (IEC 61034) |
| Acid Gas Emission | โค0.5% (IEC 60754-1) |
| Standard | IEC 60332-3 / IEC 61034 |
| Conductor Material | Aluminium / Copper |
| Insulation | XLPE (Cross-Linked Polyethylene) |
| Armour | Galvanized Steel Wire (SWA) |
| Voltage Grade | 1.1kV, 6.6kV, 11kV |
| Conductor Sizes | 16 sq.mm to 630 sq.mm |
| No. of Cores | 1C, 3C, 3.5C, 4C |
| Temperature Rating | 90ยฐC (continuous), 250ยฐC (short circuit) |
| Standard | IS 7098 / IEC 60502 |
| Installation | Underground, Duct, Cable Tray |
| Conductor Material | Stranded Copper (flexible) |
| Insulation | PVC / FR-PVC |
| No. of Cores | 2C to 61C |
| Conductor Size | 0.5, 0.75, 1.0, 1.5, 2.5 sq.mm |
| Voltage Grade | 1.1 kV |
| Shielding | Optional โ overall tinned Cu braid |
| Temperature Rating | 70ยฐC (continuous) |
| Bending Radius | Min. 6x cable OD |
| Standard | IS 694 / IS 1554 |
| Incoming Rating | Up to 6300A |
| Outgoing Feeders | DOL / Star-Delta / VFD starters |
| Bus Bar Material | Copper / Aluminium |
| Fault Level | Up to 50 kA (1 sec) |
| Voltage | 415V, 3-Phase, 50 Hz |
| Protection Degree | IP42 / IP54 |
| Form of Separation | Form 1 to Form 4b (IEC 61439) |
| Standard | IEC 61439-1/2 / IS 8623 |
| Metering | Ammeter, Voltmeter, Energy Meter |
| Control Supply | 230V AC / 110V AC / 24V DC |
| Incoming Rating | Up to 6300A |
| Incoming Device | ACB / MCCB with motorized operation |
| Outgoing Feeders | MCCBs / ACBs up to 1600A |
| Bus Bar Fault Level | Up to 65 kA (1 sec) |
| Voltage | 415V, 3-Phase, 50 Hz |
| Protection | Overcurrent, Earth Fault, Differential |
| Metering | Digital energy meter, PF meter, MD indicator |
| Standard | IEC 61439-1/2 / IS 8623 |
| Protection Degree | IP42 / IP54 |
| Incoming Rating | Up to 400A |
| Incoming Device | MCCB / Isolator |
| Outgoing Devices | MCBs (1P, 2P, 3P, 4P) |
| No. of Outgoing Ways | 4 to 72 ways |
| Voltage | 240/415V AC |
| Protection | Overcurrent, ELCB (optional) |
| Enclosure | Sheet steel, powder-coated |
| Protection Degree | IP41 / IP54 |
| Standard | IEC 61439-3 / IS 8623 |
| Material | Electrolytic Copper (99.9% purity) |
| Current Rating | 100A to 4000A |
| Voltage Rating | Up to 1000V AC |
| Cross-Sections | 10ร3 mm to 120ร10 mm |
| Surface Finish | Bare / Tin-plated / Silver-plated |
| Fault Level | Up to 80 kA (1 sec) |
| Temperature Rise | โค70K above ambient |
| Standard | IEC 61439 / IS 8623 |
| Insulation | PVC insulated / Bare with supports |
| Measured Parameters | V, I, kW, kVAr, kVA, PF, Hz, kWh, kVArh |
| Accuracy Class | Class 0.5S (IEC 62053-22) |
| Current Input | 1A or 5A CT secondary |
| Voltage Input | 110Vโ400V AC (direct / VT) |
| Frequency | 45โ65 Hz |
| Display | Backlit LCD, 4-line |
| Communication | Modbus RTU (RS-485) |
| Digital I/O | 2 Digital Inputs, 2 Relay Outputs |
| Protection Degree | IP54 (front face) |
| Standard | IEC 62052-11 / IEC 62053-22 |
| Conductor Size | 1.5 sq.mm to 240 sq.mm |
| Rated Voltage | Up to 1000V AC |
| Rated Current | Up to 232A (240 sq.mm size) |
| Connection Type | Screw / Spring / Push-in |
| Material | PA66 (Polyamide) |
| Rail Mounting | DIN TH35 (EN 60715) |
| Temperature Rating | -50ยฐC to +130ยฐC |
| Protection Degree | IP20 |
| Standard | IEC 60947-7-1 |
| Colour Coding | Grey, Blue, Green/Yellow, Red, Black |
| CPU Types | CPU 1211C, 1212C, 1214C, 1215C, 1217C |
| Onboard DI/DO | 6 DI / 4 DO to 14 DI / 10 DO (CPU dependent) |
| Onboard AI/AO | 2 AI / โ to 2 AI / 2 AO (CPU dependent) |
| Work Memory | 75KB to 150KB (CPU dependent) |
| Program Memory | 1MB to 4MB Flash |
| Communication | PROFINET (1 port), Point-to-Point, USS, Modbus |
| Programming SW | STEP 7 (TIA Portal V13+) |
| Motion Control | Up to 8 axes (CPU 1215C/1217C) |
| Supply Voltage | 24V DC / 120-240V AC |
| Operating Temp | 0ยฐC to +55ยฐC |
| CPU Types | CPU 1511, 1513, 1515, 1516, 1517, 1518 |
| Bit Processing Speed | 1 ns (CPU 1518) |
| Work Memory | 150KB to 60MB (CPU dependent) |
| Max. I/O Modules | Up to 32 modules per rack |
| Communication | PROFINET, PROFIBUS DP, Industrial Ethernet |
| Integrated Display | Yes โ 3.3" TFT (all CPUs) |
| Motion Control | Up to 128 axes (CPU 1517/1518) |
| Safety | F-CPU variants (IEC 62061 SIL3 / EN 13849 PLe) |
| Redundancy | R/H CPU variants for hot-standby redundancy |
| Operating Temp | 0ยฐC to +60ยฐC |
| Onboard DI/DO | 16 to 40 I/O (model dependent) |
| Analogue I/O | Via expansion modules TM3 |
| Program Memory | 512KB |
| Communication | Ethernet, USB Mini-B, Serial (RS-232/RS-485) |
| Protocols Supported | Modbus TCP, Modbus RTU, EtherNet/IP |
| Programming SW | EcoStruxure Machine Expert โ Basic |
| Expansion | Up to 14 TM3 expansion modules |
| Supply Voltage | 24V DC / 100-240V AC |
| Operating Temp | 0ยฐC to +55ยฐC |
| Protection Degree | IP20 |
| Max. I/O Points | Up to 1024 DI/DO + 256 AI/AO |
| Program Memory | Up to 8MB |
| Communication | Ethernet (Modbus TCP, EtherNet/IP), Modbus RTU |
| Optional Buses | PROFIBUS DP Master/Slave, CANopen, AS-Interface |
| Programming SW | Unity Pro / EcoStruxure Control Expert |
| Redundancy | Available (Hot Standby) |
| Operating Temp | 0ยฐC to +60ยฐC |
| Supply Voltage | 24V DC / 100-240V AC (PSU module) |
| Rack Size | 4, 8, 12 slot racks |
| Power Range | 0.37 kW to 250 kW |
| Input Voltage | 3-Phase 380โ480V AC (ยฑ10%) |
| Output Frequency | 0 Hz to 550 Hz |
| Control Modes | V/f, Vector (sensorless / encoder), Servo |
| Control Units | CU230P-2, CU240B-2, CU240E-2, CU250S-2 |
| Communication | PROFINET, PROFIBUS DP, Modbus RTU, USS |
| Protection Degree | IP20 (PM240-2) / IP55 (PM240P-2) |
| Overload Capacity | 150% for 60 sec (High Overload) |
| Operating Temp | -10ยฐC to +55ยฐC |
| Standards | IEC 61800-5-1 / UL 508C / CE / cULus |
| Power Range | 0.18 kW to 800 kW |
| Input Voltage | 1-Phase 200-240V / 3-Phase 380-480V AC |
| Output Frequency | 0.1 Hz to 599 Hz |
| Control Modes | V/f, Sensorless Flux Vector, Closed-loop Vector |
| Communication | Modbus RTU, CANopen, EtherNet/IP, PROFIBUS (option) |
| Protection Degree | IP21 / IP55 (ATV630/ATV930) |
| Overload Capacity | 110% / 150% for 60 sec |
| Operating Temp | -10ยฐC to +50ยฐC |
| Display | 7-segment / Graphic LCD (ATV630) |
| Standard | IEC 61800-2, IEC 61800-5-1 |
| Power Range | 0.75 kW to 250 kW |
| Input Voltage | 3-Phase 380โ480V AC (ยฑ10%) |
| Control Modes | Scalar (V/Hz), Vector (DTC) |
| Built-in Features | EMC filter, Brake chopper, Modbus RTU |
| Communication Options | PROFIBUS DP, PROFINET, EtherNet/IP, CANopen |
| Protection Degree | IP21 / IP55 options |
| Overload Capacity | 150% for 60 sec |
| Operating Temp | -15ยฐC to +50ยฐC (standard) |
| Assistant Panel | Graphical panel with assistant texts |
| Standard | IEC 61800-5-1 / CE / UL / cUL |
| Display Size | 7" widescreen TFT (KTP700) |
| Resolution | 800 ร 480 pixels |
| Colours | 65536 colours |
| Touch Type | Resistive touch + 8 function keys |
| Communication | PROFINET (1 port, RJ45) |
| Protocols | S7-1200/1500, S7-300/400, Modbus TCP |
| Configuration SW | WinCC (TIA Portal) V13+ |
| Memory | 10MB user memory, MicroSD card slot |
| Supply Voltage | 24V DC |
| Protection Degree | IP65 (front face) |
| Display Size | 12.1" widescreen TFT |
| Resolution | 1280 ร 800 pixels |
| Colours | 16.7 million colours |
| Touch Type | Capacitive multi-touch (10-point) |
| Communication | PROFINET (2 ports), PROFIBUS DP, RS-422/485 |
| Protocols | S7-1200/1500, S7-300/400, Modbus, OPC-UA |
| User Memory | 64MB + MicroSD / USB expansion |
| Scripting | VBScript / JavaScript |
| Supply Voltage | 24V DC |
| Protection Degree | IP65 (front face) |
| Display Size Range | 3.5" to 15" (model dependent) |
| Resolution | 320ร240 to 1024ร768 pixels |
| Touch Type | Resistive / Capacitive (model dependent) |
| Communication | Ethernet (RJ45), RS-232, RS-485, USB |
| Protocols Supported | Modbus RTU/TCP, EtherNet/IP, PROFIBUS (option) |
| Configuration SW | Vijeo Designer 6.x |
| User Memory | 64MB to 512MB (model dependent) |
| Supply Voltage | 24V DC |
| Protection Degree | IP65 (front face) |
| Operating Temp | 0ยฐC to +55ยฐC |
| Rated Current | 16A to 400A |
| Poles | 3P, 4P |
| Breaking Capacity | 25 kA / 36 kA @ 415V AC |
| Trip Unit | Thermal-Magnetic (TMD) |
| Operating Voltage | Up to 690V AC |
| Frequency | 50/60 Hz |
| Frame Sizes | EZC100, EZC250, EZC400 |
| Standard | IEC/EN 60947-2 |
| Protection Class | IP40 (front face) |
| Mounting | Fixed, Plug-in, Withdrawable |
| Rated Current | 16A to 630A |
| Poles | 3P, 4P |
| Breaking Capacity | 36 kA / 50 kA @ 415V AC |
| Trip Unit | Thermal-Magnetic / Electronic |
| Operating Voltage | 415V AC / 250V DC |
| Frame Sizes | 100, 250, 400, 630 |
| Standard | IS 13947-2 / IEC 60947-2 |
| Protection Class | IP54 with cover |
| Operating Temperature | -5ยฐC to +70ยฐC |
| Mounting | Fixed / Drawout |
| Rated Current | 16A to 1600A |
| Poles | 3P, 4P |
| Breaking Capacity | 16 kA to 200 kA depending on series |
| Trip Unit | TMD (Thermal-Magnetic) / Ekip (Electronic) |
| Operating Voltage | Up to 1000V AC |
| Frame Sizes | T1(25A), T2(160A), T3(250A), T4(320A), T5(630A), T6(1600A) |
| Standard | IEC/EN 60947-2 |
| Selectivity | Full selectivity up to T6 |
| Mounting | Fixed, Plug-in, Drawout, Rear Connection |
| Communication | Ekip units: Modbus, Profibus, Ethernet |
| Current Rating | 16A, 32A, 63A, 125A |
| Voltage | 200โ250V AC / 380โ415V AC |
| Protection Degree | IP44 / IP55 / IP66 |
| Poles + Earth | 2P+E, 3P+E, 3P+N+E |
| Locking | Rotating, padlockable |
| Standard | IEC 60309-1 |
| Material | Reinforced Polyamide (PA) |
| Operating Temp. | -25ยฐC to +40ยฐC |
| Current Rating | 6A, 16A, 20A, 32A |
| Voltage | 240V AC |
| Protection Degree | IP20 (Modular), IP54 (Industrial) |
| Switch Types | 1-way, 2-way, Intermediate, Bell Press |
| Socket Types | 2-pin, 3-pin, 5-pin, Universal |
| Standard | IS 3854 / IS 1293 |
| Material | Polycarbonate / ABS |
| Frame | 1M, 2M, 4M, 6M, 8M modular |
| Conductor | Annealed Bare Copper |
| Insulation | FR PVC (Type C) |
| Core Sizes | 1.0, 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50mmยฒ |
| Voltage Grade | 1100V AC |
| Temp. Rating | 70ยฐC conductor, -15ยฐC to +70ยฐC ambient |
| Standard | IS 694 / IS 1554 Part-1 |
| Configurations | Single core, 2C, 3C, 3.5C, 4C |
| Sheath Color | Red, Blue, Yellow, Green, Black, Grey |
| Conductor | Annealed Stranded Copper |
| Insulation | HFFR (Halogen-Free FR) |
| Sheath | HFFR compound |
| Core Sizes | 1.0 to 240mmยฒ |
| Voltage Grade | 1100V AC |
| Oxygen Index | >30 (IEC 60754-2) |
| Smoke Density | <60% opacity (IEC 61034) |
| Temperature Rating | 90ยฐC conductor |
| Conductor | Stranded Annealed Copper |
| Insulation | XLPE (Cross-Linked Polyethylene) |
| Armour | Galvanised Steel Wire (SWA) |
| Outer Sheath | PVC / FRLS |
| Core Sizes | 16mmยฒ to 630mmยฒ |
| Voltage Grade | 1.1kV / 3.3kV / 6.6kV / 11kV |
| Configurations | 3C, 3.5C, 4C |
| Temperature Rating | 90ยฐC (XLPE), 250ยฐC short circuit |
| Conductor | Finely Stranded Copper |
| Insulation | FR PVC |
| Core Sizes | 0.5, 0.75, 1.0, 1.5, 2.5mmยฒ |
| No. of Cores | 2C to 61C |
| Voltage Grade | 1100V AC |
| Shielding | Aluminium Foil + Drain Wire (optional) |
| Temperature Rating | 70ยฐC PVC / 90ยฐC XLPE |
| Bending Radius | 6x cable diameter (minimum) |
| Construction | Single / Double Front, Floor Standing |
| Bus Bar | Copper, 415V, 3P+N+E |
| Incomer | ACB / MCCB (as specified) |
| Outgoing Feeders | DOL / Star-Delta / VFD Starters |
| Metering | Ammeter, Voltmeter, Power Meter |
| Protection | Overload Relay, Earth Fault Relay |
| Control Voltage | 415V / 230V / 110V AC or 24V DC |
| IP Rating | IP42 / IP54 / IP65 (as required) |
| Finish | Powder Coated, RAL 7035 standard |
| Standards | IS 8623 / IEC 61439 |
| Construction | Double Front, Floor Standing, Extensible |
| Incomer | ACB up to 6300A |
| Bus Bar Rating | 800A to 6300A (Copper) |
| Outgoing | MCCB / ACB Feeders |
| Sections | Incomer + Bus Coupler + Outgoing |
| Metering | Multifunction Power Meter, CT/PT metering |
| Control Voltage | 110V AC / 24V DC (trip coil) |
| IP Rating | IP42 / IP54 |
| Standards | IEC 61439-2 / IS 8623 |
| Protection Relays | Overcurrent, Earth Fault, Differential (optional) |
| Incomer | MCB / MCCB / RCCB (as required) |
| Outgoing Ways | 4 to 36 ways |
| Incomer Rating | Up to 250A |
| Bus Bar | Copper / Aluminium |
| Enclosure | MS / GI, Wall Mounted / Flush Mounted |
| IP Rating | IP43 / IP55 |
| Finish | Powder Coated, Grey |
| Standards | IEC 61439-3 / IS 8623 |
| Material | Electrolytic Copper (99.9%) |
| Current Rating | 100A to 1600A |
| Voltage | 690V AC |
| Cross-sections | 5ร25mm, 5ร50mm, 10ร50mm, 10ร100mm |
| Pole Configuration | 1P, 3P, 4P distribution |
| Connection | Drilling + Terminal Lug / Direct bolt-on |
| Standard | IEC 61439 |
| Finish | Tin-plated for low contact resistance |
| Accuracy Class | Class 0.5S (IEC 62053-22) |
| Measurements | V, I, kW, kVAR, kVA, PF, Hz, kWh, kVARh |
| Voltage Input | 57.7 to 400V L-N (up to 690V with VT) |
| Current Input | 1A or 5A secondary (via CT) |
| Display | Backlit LCD, 8-line |
| Communication | Modbus RTU (RS485) |
| Demand Monitoring | kW, kVAR, kVA demand + peak demand |
| Mounting | DIN Rail or Panel Cutout (92ร92mm) |
| Auxiliary Supply | 100โ415V AC or 24V DC |
| Standard | IEC 62053 / IEC 61557-12 |
| Connection Type | Screw-Clamp / Spring-Cage |
| Conductor Size | 0.5mmยฒ to 240mmยฒ |
| Rated Voltage | Up to 1000V AC |
| Rated Current | Up to 232A |
| Colors | Grey, Blue, Green-Yellow, Yellow, Red, Black |
| Mounting | DIN Rail TH35 |
| Accessories | Bridges, Markers, End Stops, Separators |
| Standard | IEC 60947-7-1 / EN 60947-7-1 |
| CPU Variants | 1211C, 1212C, 1214C, 1215C, 1217C |
| Digital I/O | 6 DI / 4 DO to 14 DI / 10 DO (on-board) |
| Analog I/O | 2 AI standard (up to 9 AI with signal boards) |
| Work Memory | 50KB to 150KB (CPU dependent) |
| Communication | PROFINET (1x or 2x port), point-to-point |
| Programming | TIA Portal V15.1 and above (LAD, FBD, STL, SCL, GRAPH) |
| Supply Voltage | 24V DC / 120-240V AC |
| Output Types | Relay / Transistor (DC) |
| Expansion | Signal Modules, Signal Boards, Communication Modules |
| Operating Temp. | 0ยฐC to +55ยฐC (horizontal), 0ยฐC to +45ยฐC (vertical) |
| CPU Variants | 1511 to 1518 (Standard, Advanced, Technology) |
| Work Memory | 150KB to 60MB (CPU dependent) |
| Max I/O | Up to 8192 digital + 2048 analog I/O points |
| Cycle Time | from 1ms (CPU 1511) to 0.016ms bit (CPU 1518) |
| Communication | PROFINET IRT, PROFIBUS, OPC UA, Industrial Ethernet |
| Motion Control | Up to 128 axes (Technology CPUs) |
| Programming | TIA Portal V16+ (LAD, FBD, STL, SCL, GRAPH, CFC) |
| Cybersecurity | Integrated access protection, integrity check |
| Display | Integrated CPU display for diagnostics |
| Safety | F-CPU variants (1511F to 1518F) up to SIL3/PLe |
| Digital I/O | 16 to 40 DI/DO (base unit) |
| Analog I/O | Via TM3 expansion modules |
| Work Memory | 256KB |
| Communication | Ethernet (Modbus TCP), Serial (Modbus RTU / ASCII) |
| Programming | EcoStruxure Machine Expert โ Basic (LD, IL, SFC, FBD) |
| Supply Voltage | 24V DC / 100-240V AC |
| Output Types | Relay / Transistor |
| High-Speed Counter | Up to 200kHz (single phase) |
| SD Card Slot | Yes โ for program backup and data logging |
| Operating Temp. | 0ยฐC to +55ยฐC |
| Max I/O | Up to 1024 DI/DO, 256 AI/AO |
| Work Memory | Up to 8MB |
| Communication | Ethernet, PROFIBUS DP, CANopen, Modbus |
| Programming | Unity Pro / EcoStruxure Control Expert (LD, FBD, SFC, ST, IL) |
| Backplane | 4 to 12 slots (expandable) |
| Redundancy | Hot standby CPU redundancy available |
| Supply | 24V DC or 100-240V AC backplane power |
| Operating Temp. | 0ยฐC to +60ยฐC |
| Standard | IEC 61131-3, IEC 61508 (SIL2 with safety modules) |
| Cybersecurity | User access control, application password protection |
| Power Range | 0.37 kW to 250 kW |
| Input Voltage | 200โ240V (1-phase), 380โ480V (3-phase) |
| Output Frequency | 0 to 550 Hz |
| Control Mode | V/f, Vector Control (sensorless/encoder), Servo |
| Communication | PROFINET, PROFIBUS, Modbus RTU, EtherNet/IP |
| Safety | STO (Safe Torque Off) โ SIL2 / PLd standard |
| Protection | IP20 (standard), IP55 (SINAMICS G120C compact) |
| Braking | Dynamic braking resistor / Regenerative (PM250) |
| Standards | IEC 61800-5-1, CE, UL listed |
| Energy Saving | Energy saving mode + energy meter built-in |
| Power Range | 0.18 kW to 15 kW (single phase: 0.18โ2.2kW) |
| Input Voltage | 200โ240V (1-phase), 380โ500V (3-phase) |
| Output Frequency | 0.5 to 500 Hz |
| Control Mode | V/f (2-point, 5-point), Sensorless Vector, Flux Vector |
| Communication | CANopen, Modbus RTU, Ethernet Modbus TCP, PROFIBUS (option) |
| Safety | STO โ SIL2/PLd (IEC 62061 / ISO 13849) |
| Protection | IP20 (booktype), IP21 / IP55 (compact) |
| Built-in Features | EMC filter, dynamic braking transistor, PID controller |
| Standards | IEC 61800-5-2, CE, UL, cULus |
| Display | Integrated display + removable keypad |
| Power Range | 0.75 kW to 355 kW |
| Input Voltage | 208โ240V, 380โ480V, 500โ600V (3-phase) |
| Output Frequency | 0 to 500 Hz |
| Control Mode | Scalar (V/f), Vector (DTC โ Direct Torque Control) |
| Communication | Modbus RTU, PROFIBUS, CANopen, DeviceNet (option modules) |
| Protection | IP21 / UL Type 1 standard; IP54 optional |
| Built-in Features | EMC filter, choke, PID, fire mode, PFC pump control |
| Energy Saving | Energy optimizer + kWh meter |
| Keypad | Assistant Control Panel with parameter copy function |
| Standards | IEC 61800-5-1, CE, UL, cULus, C-Tick |
| Display Size | 7" widescreen TFT (800ร480 pixels) |
| Colors | 65536 colors (16-bit) |
| Operation | Touch + 8 programmable function keys |
| Communication | PROFINET (1x RJ45), MPI/PROFIBUS (optional) |
| Memory | 10MB user memory |
| Engineering | TIA Portal WinCC Basic / Comfort |
| Alarms | Up to 512 alarm messages |
| Tags | Up to 500 process tags (KTP700 Basic) |
| Supply Voltage | 24V DC |
| Protection | IP65 (front panel), IP20 (rear) |
| Display Size | 12.1" widescreen TFT (1280ร800 pixels) |
| Colors | 16 million colors (24-bit) |
| Operation | Multi-touch (10-point) |
| Communication | PROFINET (2x RJ45), MPI/PROFIBUS, USB, SD Card |
| Memory | 24MB user memory |
| Engineering | TIA Portal WinCC Comfort |
| Alarms | Up to 32768 alarm classes |
| PLC Connections | Up to 6 simultaneous |
| Data Logging | SD card / USB up to 32GB |
| Supply Voltage | 24V DC |
| Display Sizes | 10", 12", 15" (widescreen TFT) |
| Resolution | 1024ร600 (10"), 1280ร800 (12"), 1280ร800 (15") |
| Colors | 16 million colors (24-bit TFT) |
| Processor | 1GHz ARM Cortex-A8 |
| RAM / Flash | 512MB RAM / 512MB Flash |
| Communication | Ethernet (2รRJ45), Serial (COM1/COM2), USB, SD Card |
| Protocols | Modbus TCP/RTU, EtherNet/IP, PROFIBUS, CAN, Uni-Telway |
| Engineering Tool | Vijeo Designer (free, offline) |
| Supply Voltage | 24V DC |
| Protection | IP66 (front panel) |
| Current Range (AC-3) | 9A to 150A |
| Motor Power (AC-3, 415V) | 4 kW to 75 kW |
| Poles | 3P main + 1 NO auxiliary (standard) |
| Coil Voltage | 24V, 48V, 110V, 220V, 415V AC/DC options |
| Operating Frequency | Up to 3600 operations/hour (AC-3) |
| Mechanical Endurance | Up to 30 million operations |
| Mounting | DIN Rail or screw |
| Standards | IEC/EN 60947-4-1, IS 13947-4-1 |
| Accessories | Auxiliary blocks, timer modules, surge suppressors, mechanical interlocks |
| Reversing Contactors | LC2D (factory-assembled reversing pair) |
| Current Range (AC-3) | 9A to 125A |
| Motor Power (AC-3, 415V) | 4 kW to 55 kW |
| Poles | 3P + 1 NO / 1 NC auxiliary |
| Coil Voltage | 24V, 110V, 230V, 415V AC; 24V, 110V DC |
| Coil Voltage Tolerance | 85% to 110% of rated voltage (pick-up) |
| Operating Temp. | Up to +60ยฐC ambient |
| Mounting | DIN Rail 35mm / Panel Screw |
| Standards | IS 13947-4-1 / IEC 60947-4-1 |
| Mechanical Endurance | 20 million operations |
| Thermal Relay | Compatible with L&T MO-type thermal overload relays |
| I/O Count | 10 to 40 I/O (model dependent) |
| Digital Inputs | 6 to 24 DI (with analogue variants) |
| Relay Outputs | 4 to 16 relay outputs |
| Display | Backlit LCD with keypad (Smart models) |
| Programming | Ladder (LD) or Function Block (FBD) โ Zelio Soft 2 |
| Communication | RS485 Modbus RTU (extended models) |
| Supply Voltage | 24V DC / 100-240V AC |
| Clock / Calendar | Built-in real-time clock (24h / weekly / annual programs) |
| Memory | Cartridge-based program storage |
| Timers / Counters | Up to 32 timers, 16 counters |
| Motor Power Range | 0.37 kW to 22 kW (DOL) |
| Supply Voltage | 415V AC, 3-phase |
| Control Voltage | 415V / 230V / 110V (as specified) |
| Contactor | L&T MNX Series (matched to motor kW) |
| Overload Relay | L&T MO-type bimetallic โ adjustable |
| Enclosure | Open (DIN rail) / IP54 GI enclosure |
| Pushbuttons | Green (Start) + Red (Stop) + Emergency Stop |
| Indication | Run / Trip indication lamps |
| Standards | IS 13947-4-1 / IEC 60947-4-1 |
| Overload Setting | Adjustable 0.75ร to 1ร In |
| Motor Power Range | 18.5 kW to 250 kW |
| Supply Voltage | 415V AC, 3-phase |
| Starting Current | 33% of DOL starting current |
| Contactor Set | 3ร TeSys D (Main, Star, Delta) |
| Timer Type | Electronic timer relay (0.3s to 300s range) |
| Overload Relay | Schneider LRD thermal overload relay |
| Control Voltage | 24V DC / 110V / 230V / 415V AC |
| Enclosure | GI powder-coated, IP54 standard |
| Transition | Open transition (standard) / Closed transition (optional) |
| Standards | IEC 60947-4-1 |
| Sensing Principle | Electromagnetic Induction |
| Target Material | Ferrous metals (standard), all metals (factor 1 versions) |
| Sensing Range | 2mm to 20mm (housing size dependent) |
| Housing Sizes | M8, M12, M18, M30 (cylindrical); rectangular |
| Output Type | PNP / NPN, NO / NC |
| Supply Voltage | 10โ30V DC |
| Switching Frequency | Up to 5000 Hz |
| Protection Degree | IP67 (standard), IP69K (wash-down versions) |
| Connection | M12 connector or cable |
| Standards | IEC 60947-5-2, cULus, CE |
| Operating Modes | Through-beam, Retroreflective, Diffuse, Background Suppression |
| Light Source | Infrared LED / Red LED / Laser (Class 1 or 2) |
| Sensing Range | 0.02m to 60m (mode dependent) |
| Output Type | PNP / NPN, Light-ON / Dark-ON (selectable) |
| Supply Voltage | 10โ30V DC |
| Response Time | <1ms (standard) |
| Light Spot Size | Adjustable beam in OMNIPROX series |
| Protection Degree | IP67 (standard) |
| Connection | M12 connector, 4-pin / 5-pin |
| Standards | IEC 60947-5-2, EN 61496 (safety versions) |
| Sensing Range | 0.06m to 10m (model dependent) |
| Detection Method | Time-of-flight ultrasonic pulse |
| Target Materials | Any solid or liquid โ material-independent |
| Output Types | PNP/NPN switching + 4โ20mA / 0โ10V analog |
| Supply Voltage | 15โ30V DC |
| Response Time | 48ms (standard), 16ms (fast models) |
| Housing | M18, M30, cylindrical plastic |
| Blind Zone | 40mm to 200mm (model dependent) |
| Protection Degree | IP67 |
| Connection | M12 connector |
| Sensing Principle | Capacitive (electrostatic field change) |
| Target Materials | Non-metals โ liquids, powder, granules, plastics, wood |
| Sensing Range | 2mm to 20mm (adjustable sensitivity) |
| Through-Wall Detection | Yes โ through glass, plastic, non-metallic containers |
| Sensitivity | Adjustable potentiometer |
| Output Type | PNP / NPN, NO / NC |
| Supply Voltage | 10โ30V DC |
| Housing Sizes | M18, M30 cylindrical |
| Protection Degree | IP67 |
| Standards | IEC 60947-5-2, CE, cULus |